ArticleJournal of visualized experiments : JoVE2016
Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 1. Biosafety Level 4 Suit Laboratory Suite Entry and Exit Procedures.
Article in Journal of visualized experiments : JoVE, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Synchrotron-based multi-scale biological imaging inside biocontainment environments.Journal of synchrotron radiation · 2026Article
- Modeling Risk Group 4 virus infection and antiviral treatment in microfluidic lung organ-on-chips in maximum containment laboratories.bioRxiv : the preprint server for biology · 2026Article
- Decontamination Validation of the BSL-4 Chemical Disinfectant Deluge Shower System.Applied biosafety : journal of the American Biological Safety Association · 2024Article
- An airlock concept to reduce contamination risks during the human exploration of Mars.NPJ microgravity · 2023Article
- Challenges and Opportunities in the Use of High and Maximum Biocontainment Facilities in Developing and Licensing Risk Group 3 and Risk Group 4 Agent Veterinary Vaccines.ILAR journal · 2022Article
- Biologically-Based and Physiochemical Life Support and In Situ Resource Utilization for Exploration of the Solar System-Reviewing the Current State and Defining Future Development Needs.Life (Basel, Switzerland) · 2021Review
- Article
- The ReFRAME library as a comprehensive drug repurposing library to identify mammarenavirus inhibitors.Antiviral research · 2019Article
- Article
- Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 3. Aerobiology.Journal of visualized experiments : JoVE · 2016Article
- Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 2. General Practices.Journal of visualized experiments : JoVE · 2016Article
- Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 4. Medical Imaging Procedures.Journal of visualized experiments : JoVE · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
Biosafety level 4 (BSL-4) suit laboratories are specifically designed to study high-consequence pathogens for which neither infection prophylaxes nor treatment options exist. The hallmarks of these laboratories are: custom-designed airtight doors, dedicated supply and exhaust airflow systems, a negative-pressure environment, and mandatory use of positive-pressure ("space") suits. The risk for laboratory specialists working with highly pathogenic agents is minimized through rigorous training and adherence to stringent safety protocols and standard operating procedures. Researchers perform the majority of their work in BSL-2 laboratories and switch to BSL-4 suit laboratories when work with a high-consequence pathogen is required. Collaborators and scientists considering BSL-4 projects should be aware of the challenges associated with BSL-4 research both in terms of experimental technical limitations in BSL-4 laboratory space and the increased duration of such experiments. Tasks such as entering and exiting the BSL-4 suit laboratories are considerably more complex and time-consuming compared to BSL-2 and BSL-3 laboratories. The focus of this particular article is to address basic biosafety concerns and describe the entrance and exit procedures for the BSL-4 laboratory at the NIH/NIAID Integrated Research Facility at Fort Detrick. Such procedures include checking external systems that support the BSL-4 laboratory, and inspecting and donning positive-pressure suits, entering the laboratory, moving through air pressure-resistant doors, and connecting to air-supply hoses. We will also discuss moving within and exiting the BSL-4 suit laboratories, including using the chemical shower and removing and storing positive-pressure suits.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.