Evidence map›Paper›PMID 27761614›Full record

ArticleAnalytical and bioanalytical chemistry2017

Monitoring cell secretions on microfluidic chips using solid-phase extraction with mass spectrometry.

Colleen E Dugan, James P Grinias, Sebastian D Parlee, Mahmoud El-Azzouny, Charles R Evans, Robert T Kennedy

Abstract read
In one paragraph

Article in Analytical and bioanalytical chemistry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Review of 3D Cell Culture with Analysis in Microfluidic Systems.Analytical methods : advancing methods and applications · 2019
    Article
  14. Article
  15. Article
  16. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Colleen E DuganDepartment of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA.
James P GriniasDepartment of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA.
Sebastian D ParleeDepartment of Molecular & Integrative Physiology, University of Michigan, Ann Arbor, MI, 48109, USA.
Mahmoud El-AzzounyDepartment of Internal Medicine, University of Michigan, Ann Arbor, MI, 48109, USA.
Charles R EvansDepartment of Internal Medicine, University of Michigan, Ann Arbor, MI, 48109, USA.
Robert T KennedyDepartment of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA. rtkenn@umich.edu.

Funding

Regional Pilot And Feasibility Study Grants ProgramP30DK020572 · NIDDK · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Scott Soleimanpour · 2013 to 2026
$24.3M
Statistics and Bioinformatics Core - WangU24DK097153 · NIDDK · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI BURANT, CHARLES F · 2012 to 2017
$10.1M
MICROELECTRODE AND MICRODIALYSIS-BASED INSULIN SENSORSR01DK046960 · NIDDK · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI KENNEDY, ROBERT T · 1993 to 2020
$3.3M
Design and Use of Methods for Peptide Secretion Studies - Diversity SupplementR37DK046960 · NIDDK · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI KENNEDY, ROBERT T · 2006 to 2015
$3.0M
Microfabricated Liquid Chromatography System for Analysis of NeurotransmittersF32EB019800 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI GRINIAS, JAMES P · 2015 to 2016
$68k
NIBIB NIH HHS F32 EB019800NIDDK NIH HHS P30 DK020572NIDDK NIH HHS R01 DK046960NIDDK NIH HHS R37 DK046960NIDDK NIH HHS U24 DK097153
6 · The paper itself

Abstract

Microfluidics is an enabling technology for both cell biology and chemical analysis. We combine these attributes with a microfluidic device for on-line solid-phase extraction (SPE) and mass spectrometry (MS) analysis of secreted metabolites from living cells in culture on the chip. The device was constructed with polydimethylsiloxane (PDMS) and contains a reversibly sealed chamber for perfusing cells. A multilayer design allowed a series of valves to control an on-chip 7.5 μL injection loop downstream of the cell chamber with operation similar to a six-port valve. The valve collects sample and then diverts it to a packed SPE bed that was connected in-line to treat samples prior to MS analysis. The valve allows samples to be collected and injected onto the SPE bed while preventing exposure of cells to added back pressure from the SPE bed and organic solvents needed to elute collected chemicals. Here, cultured murine 3T3-L1 adipocytes were loaded into the cell chamber and non-esterified fatty acids (NEFAs) that were secreted by the cells were monitored by SPE-MS at 30 min intervals. The limit of detection for a palmitoleic acid standard was 1.4 μM. Due to the multiplexed detection capabilities of MS, a variety of NEFAs were detected. Upon stimulation with isoproterenol and forskolin, secretion of select NEFAs was elevated an average of 1.5-fold compared to basal levels. Despite the 30-min delay between sample injections, this device is a step towards a miniaturized system that allows automated monitoring and identification of a variety of molecules in the extracellular environment.

Indexed as

3T3-L1 CellsAdipocytesAnimalsEquipment DesignFatty Acids, NonesterifiedLab-On-A-Chip DevicesMass SpectrometryMiceMicrofluidic Analytical TechniquesSolid Phase ExtractionFatty Acids, NonesterifiedAdipocyteAutomationIntegrationMass spectrometryMicrofluidicSolid-phase extraction

Identifiers

PMID27761614
PMCPMC5203966

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.