Comparison of invasive and brachial cuff-based noninvasive measurements for the assessment of blood pressure amplification.

Atsushi Nakagomi, Sho Okada, Toshihiro Shoji, Yoshio Kobayashi

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Hypertension research : official journal of the Japanese Society of Hypertension, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it, 23 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Systolic blood pressure amplification and waveform calibration.Hypertension research : official journal of the Japanese Society of Hypertension · 2017
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Atsushi NakagomiDepartment of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan.
Sho OkadaDepartment of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan.
Toshihiro ShojiDepartment of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan.
Yoshio KobayashiDepartment of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan.
Chiba University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Our aim was to assess the discrepancy in the blood pressure amplification (BPA) value defined as the aortic-to-brachial increase in systolic BP (SBP) between invasive and noninvasive brachial cuff-based methods. In 45 patients undergoing cardiac catheterization, BP in the brachial artery and ascending aorta were measured with an invasive catheter and a brachial cuff-based oscillometric device. To calculate aortic SBP, brachial waveforms were calibrated by the brachial systolic and diastolic BP (DBP) (C1 calibration) or by the brachial mean BP and DBP (C2 calibration). C1 calibration underestimated aortic SBP (-17.7 mm Hg (95% confidence interval: -21.9 to -13.5)), whereas C2 calibration generated an approximately accurate aortic SBP (1.8 mm Hg (-2.4 to 5.9)). Regarding brachial SBP, noninvasively measured values were markedly underestimated (22.2 mm Hg (-26.4 to -18.0)), resulting in a slightly low BPA value in C1 calibration (11.9±6.3 mm Hg) and a paradoxical negative BPA value in C2 calibration (-7.6±6.7 mm Hg). Multiple linear regression analysis showed that the cuff-catheter difference of BPA was positively correlated with the cuff-catheter difference of brachial SBP in both calibrations (C1 calibration: β=0.51; C2 calibration: β=0.50; both P<0.01). Although noninvasively measured BPA was associated with invasively measured BPA only in C1 calibration (r=0.33, P=0.03), when using invasively measured brachial SBP instead of a cuff-based measurement, the BPA was well associated with invasively measured BPA in both calibrations (C1 calibration: r=0.57; C2 calibration: r=0.52; both P<0.001). In conclusion, there was a trade-off in accuracy between brachial cuff-based noninvasive aortic SBP and BPA because of the inherent inaccuracies in the cuff-based method. This finding should be fully considered in establishing standardized reference values for aortic BP.

Indexed as

AgedBlood PressureBlood Pressure DeterminationCoronary AngiographyFemaleHemodynamicsHumansMaleMiddle AgedOscillometry

Identifiers

PMID27761001
OpenAlexW2533705375

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.