Evidence map›Paper›PMID 27760058›Full record

ArticleInvestigative radiology2016

Time-of-Arrival Parametric Maps and Virtual Bolus Images Derived From Contrast-Enhanced Time-Resolved Radial Magnetic Resonance Angiography Improve the Display of Brain Arteriovenous Malformation Vascular Anatomy.

Tilman Schubert, Yijing Wu, Kevin M Johnson, Oliver Wieben, Jane Maksimovic, Charles Mistretta, Patrick Turski

Abstract read
In one paragraph

Article in Investigative radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Quantitative evaluation of arteriovenous malformation hemodynamic changes after endovascular treatment using parametric color coding: A case series study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tilman SchubertFrom the *Department of Radiology, University of Wisconsin-Madison, Madison, WI; †Clinic for Radiology and Nuclear Medicine, Basel University Hospital, Basel, Switzerland; and ‡Department of Medical Physics, University of Wisconsin-Madison, Madison, WI.
Yijing Wu
Kevin M Johnson
Oliver Wieben
Jane Maksimovic
Charles Mistretta
Patrick Turski

Funding

Accelerated Neuro-MRA Using Compressed Sensing and Constrained ReconstructionR01NS066982 · NINDS · UNIVERSITY OF WISCONSIN-MADISON · PI JOHNSON, KEVIN MICHAEL, TURSKI, PATRICK ALAN · 2010 to 2018
$2.7M
Functional Magnetic Resonance Angiography (fMRA) of the BrainR21EB009441 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI TURSKI, PATRICK ALAN · 2009 to 2010
$399k
NIBIB NIH HHS R21 EB009441NINDS NIH HHS R01 NS066982
6 · The paper itself

Abstract

objectivesTime-of-arrival (TOA) maps can be derived from high-resolution 4-dimensional (4D) contrast-enhanced magnetic resonance angiography (MRA) data sets to provide a quantitative description of contrast material arrival time in each voxel. This information can further be processed to create a compressed time evolution curve that virtually shortens the contrast bolus (virtual bolus [VB]). The purpose of this project was to determine whether TOA-enhanced 4D MRA and/or VB imaging improve the display of contrast kinetics in patients with vascular disease.

methodsHigh-resolution whole-brain contrast-enhanced 4D MRA examinations with 1.2-second temporal reconstruction were acquired by using radial acquisition and highly constrained projection reconstruction (radial 4D contrast-enhanced HYPRFlow, abbreviated as HFMRA in this article) in 10 patients (8 patients with arteriovenous malformations [AVM], 1 patient with an arteriovenous fistula, and 1 patient with a high-grade intracranial stenosis). The TOA for each voxel was defined as the time point when the signal intensity reached 20% of its maximum. In the first method, TOA maps were generated, color-encoded, and then multiplied with the time-resolved contrast-enhanced MRA images at each time frame to form new 4D MRA images (TOA-enhanced HFMRA), which contains the contrast arrival times with defined color encoding. In the second method, each time frame was weighted by a Gaussian distribution in the time domain to form a virtual 4D bolus map. This 4D bolus map was then color-coded and multiplied with the HFMRA images to form a digital subtraction angiography (DSA)-like VB, where at each time frame, only vessels with certain TOA values within the defined bolus length appear. HFMRA, TOA maps, and VB images were scored qualitatively with regard to delineation of arteries, veins, and nidus, as well as artifacts. Furthermore, diagnostic confidence and arteriovenous overlap were evaluated and compared between techniques. A comparison with DSA was performed where DSA served as the reference standard in terms of number of arterial feeders, draining veins, and Spetzler-Martin score of AVMs. In addition, TOA maps were evaluated quantitatively.

resultsOverall, diagnostic confidence score of TOA was significantly higher compared with that of HFMRA (P = 0.03). Virtual bolus showed significantly higher scores for overall diagnostic confidence (P = 0.02) and reduced arteriovenous overlap (0.01) compared with HFMRA. Furthermore, VB-reduced arteriovenous overlap scores were significantly higher compared with TOA (P = 0.04). Agreement regarding AVM draining veins was lower between DSA and HFMRA (κ = 0.3) compared with TOA and VB (κ = 0.56). Agreement regarding Spetzler-Martin score was lower between DSA and HFMRA (κ = 0.56) compared with TOA and VB (κ = 0.74).

conclusionsTOA-enhanced HFMRA provides serial images and time of arrival maps in one inclusive display. In this study, TOA mapping combined with Virtual Bolus imaging improved diagnostic confidence in AVM patients and facilitated arteriovenous separation. The VB method further reduced overlap of arterial and venous structures.

Indexed as

Contrast MediaAdultArtifactsBrainFemaleHumansImage EnhancementImage Processing, Computer-AssistedImaging, Three-DimensionalIntracranial Arteriovenous MalformationsMagnetic Resonance AngiographyMaleProspective StudiesTime FactorsContrast Media

Identifiers

PMID27760058
PMCPMC5119764

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.