ArticleJournal of the American Society for Mass Spectrometry2017
Increased Ion Transmission for Differential Ion Mobility Combined with Mass Spectrometry by Implementation of a Flared Inlet Capillary.
Article in Journal of the American Society for Mass Spectrometry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 8 citations in OpenAlex.
- Performance Enhancements in Differential Ion Mobility Spectrometry-Mass Spectrometry (DMS-MS) by Using a Modified CaptiveSpray Source.Journal of the American Society for Mass Spectrometry · 2018Article
- Resolution and Assignment of Differential Ion Mobility Spectra of Sarcosine and Isomers.Journal of the American Society for Mass Spectrometry · 2018Article
- Variables Affecting the Internal Energy of Peptide Ions During Separation by Differential Ion Mobility Spectrometry.Journal of the American Society for Mass Spectrometry · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Differential ion mobility spectrometry (DIMS) is capable of separating components of complex mixtures prior to mass spectrometric analysis, thereby increasing signal-to-noise and signal-to-background ratios on millisecond timescales. However, adding a DIMS device to the front end of a mass spectrometer can reduce the signal intensity of subsequent mass spectrometric analysis. This is a result, in part, of ions lost due to inefficient transfer of ions from the DIMS device through the aperture leading into the mass spectrometer. This problem of transferring ions can be at least partially corrected by modifying the front end of the inlet capillary leading to the vacuum of the mass spectrometer. The inner diameter of the ion-sampling end of the inlet capillary was enlarged by drilling into the face. This results in a conical flare at the front end of the capillary, while the other end of the capillary remains unmodified. These flared capillaries allow for a greater number of ions from the DIMS device to be sampled relative to the unmodified standard capillary. Four flare dimensions were tested, differing by the angle between the wall of the flare and the outer wall of the inlet capillary. All flared capillaries showed greater signal intensity than the standard capillary with a DIMS device present without reducing the resolving power. It was also observed that the signal intensity increased as the flare angle decreased. The flared capillary with the smallest flare angle showed greater than a fivefold increase in signal intensity compared with the standard capillary. Graphical Abstract ᅟ.