Evidence map›Paper›PMID 27747683›Full record

ArticleDrug safety - case reports2016

Difficulty Using Smart Pump Logs to Recreate a Patient Safety Event: Case Study and Considerations for Pump Enhancements.

Andrew A M Ibey, Derek Andrews, Barb Ferreira

Open access · hybridAbstract read
In one paragraph

Article in Drug safety - case reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Data-based program management of system-wide IV smart pump integration.American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Andrew A M IbeyDepartment of Biomedical Engineering, Providence Healthcare, Vancouver General Hospital, 855 West 12th Ave, Vancouver, BC, V5Z 1M9, Canada. aibey@providencehealth.bc.ca.ORCID http://orcid.org/0000-0003-1632-8038
Derek AndrewsDepartment of Pharmacy, Vancouver Coastal Health, Lions Gate Hospital, North Vancouver, BC, Canada.
Barb FerreiraDepartment of Acute and Chronic Health, Vancouver Coastal Health, Lions Gate Hospital, North Vancouver, BC, Canada.
Vancouver Coastal Health · CAProvidence Health Care · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The authors present a case in which a physical anomaly with an infusion pump resulted in an unforeseen fault that the nurse's attempts to resolve unknowingly exacerbated. This case study presents the first report in the literature to detail the difficulty in recreating a patient safety event using smart pump logs, support server continuous quality improvement (CQI) data, and the drug order entry system to elucidate the clinical scenario. A 75-year-old male patient presented to a major teaching hospital and was admitted to the intensive care unit (ICU) with a massive gastrointestinal bleed and myocardial infarction, then stabilized. One of the patient's pumps alarmed "communication error" on the display. The display gave no explicit instructions about how to resolve the issue, and resolution was not intuitive. Attempts to clear the alarm failed, so the module was disconnected to reprogram the infusion, causing an interruption in the dopamine. Over the course of approximately 2 min of troubleshooting, the patient's blood pressure decreased from 109/50 to 60/30, with a rapid pulse change from a consistent 95 up to 115 and subsequently 135 beats per minute. A cardiac arrest ensued and a code blue was called. All cardiac drugs, including the dopamine, were suspended during the code. Cardiopulmonary resuscitation was performed and the patient survived the code. Post-code, the dopamine and epinephrine were restarted, and the norepinephrine was discontinued. The patient's condition remained very unstable. Pump logs and the server database were queried to locate relevant equipment. It was concluded that dirty contacts on the inter-unit interface (IUI) connectors between the PC unit (PCU) and the modules caused the alarm message "communication error" to appear on the PCU display. Learning yielded a nursing practice alert to clarify how a nurse should resolve a "communication error", and appropriate cleaning protocols were promptly implemented. The investigation found smart pump event logs and proprietary software are not designed with any forethought as to retrospective reconstruction of incident investigations, leaving facilities to cobble together pieces of information from multiple sources to determine what occurred. The authors also suggest further pump enhancements, challenging pump manufacturers to go to the next level of integration and enable greater patient safety with smart infusion pumps.

Identifiers

PMID27747683
PMCPMC5005606
OpenAlexW2336292745

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.