ArticleMedical & biological engineering & computing2017
Detection of exercise periodic breathing using thermal flowmeter in patients with heart failure.
Article in Medical & biological engineering & computing, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Analysis of Exercise-Induced Periodic Breathing Using an Autoregressive Model and the Hilbert-Huang Transform.Computational and mathematical methods in medicine · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Exercise periodic breathing (EPB) is associated with exercise intolerance and poor prognosis in patients with heart failure (HF). However, EPB detection during cardiopulmonary exercise test (CPET) is difficult. The present study investigated the use of a wireless monitoring device to record the EPB during CPET and proposed quantization parameter estimates for the EPB. A total of 445 patients with HF were enrolled and underwent exercise tests. The ventilation data from the wearable device were compared with the data obtained during the CPET and were analyzed based on professional opinion and on 2 automated programs (decision tree [DT] and oscillatory pattern methods). The measurement accuracy was greater with the DT method (89 %) than with the oscillatory pattern method (75 %). The cutoffs for EPB recognition using the DT method were (1) an intercept of the regression line passing through the minute ventilation rate vs. the time curve during the recovery phase ≥64.63, and (2) an oscillatory phase duration to total exercise time ratio ≥0.5828. The wearable device was suitable for the assessment of EPB in patients with HF, and our new automated analysis system using the DT method effectively identified the EPB pattern.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.