Detection of exercise periodic breathing using thermal flowmeter in patients with heart failure.

Tieh-Cheng Fu, Wen-Chen Lin, Jong-Shyan Wang, Chao-Hung Wang, Chun-Tien Chang, Cheng-Lun Tsai, Yun-Shien Lee, Kang-Ping Lin

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 1 country.

Tieh-Cheng FuDepartment of Physical Medicine and Rehabilitation, Chang Gung Memorial Hospital, Keelung, Taiwan.
Wen-Chen LinTechnology Translation Center for Medical Device, Chung Yuan Christian University, Tao-Yuan, Taiwan.
Jong-Shyan WangDepartment of Physical Medicine and Rehabilitation, Chang Gung Memorial Hospital, Keelung, Taiwan.
Chao-Hung WangHeart Failure Center, Department of Internal Medicine, Chang Gung Memorial Hospital, Keelung, Taiwan.
Chun-Tien ChangComputer and Communication Center, National Tsing Hua University, Hsinchu, Taiwan.
Cheng-Lun TsaiTechnology Translation Center for Medical Device, Chung Yuan Christian University, Tao-Yuan, Taiwan.
Yun-Shien LeeDepartment of Biotechnology, Ming-Chuan University, Kwei-Shan, Tao-Yuan, Taiwan.
Kang-Ping LinTechnology Translation Center for Medical Device, Chung Yuan Christian University, Tao-Yuan, Taiwan. kplin@cycu.edu.tw.
Chung Yuan Christian University · TWKeelung Chang Gung Memorial Hospital · TWChang Gung University · TWMing Chuan University · TWNational Tsing Hua University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Exercise periodic breathing (EPB) is associated with exercise intolerance and poor prognosis in patients with heart failure (HF). However, EPB detection during cardiopulmonary exercise test (CPET) is difficult. The present study investigated the use of a wireless monitoring device to record the EPB during CPET and proposed quantization parameter estimates for the EPB. A total of 445 patients with HF were enrolled and underwent exercise tests. The ventilation data from the wearable device were compared with the data obtained during the CPET and were analyzed based on professional opinion and on 2 automated programs (decision tree [DT] and oscillatory pattern methods). The measurement accuracy was greater with the DT method (89 %) than with the oscillatory pattern method (75 %). The cutoffs for EPB recognition using the DT method were (1) an intercept of the regression line passing through the minute ventilation rate vs. the time curve during the recovery phase ≥64.63, and (2) an oscillatory phase duration to total exercise time ratio ≥0.5828. The wearable device was suitable for the assessment of EPB in patients with HF, and our new automated analysis system using the DT method effectively identified the EPB pattern.

Indexed as

Breath TestsCheyne-Stokes RespirationDiagnosis, Computer-AssistedEquipment DesignEquipment Failure AnalysisExercise TestFemaleHeart FailureHumansMaleMiddle AgedOscillometryReproducibility of ResultsRespiratory MechanicsRheologySensitivity and SpecificityHeart failurePeriodic breathingPulmonary ventilationWearable device