Evidence map›Paper›PMID 27741287›Full record

ArticlePloS one2016

Establishment of Epithelial Attachment on Titanium Surface Coated with Platelet Activating Peptide.

Shiho Sugawara, Masahiko Maeno, Cliff Lee, Shigemi Nagai, David M Kim, John Da Silva, Masazumi Nagai, Hisatomo Kondo

Abstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Review
  4. Review
  5. Peptides in Dentistry: A Scoping Review.Bioengineering (Basel, Switzerland) · 2023
    Article
  6. Article
  7. Role of chitosan in titanium coatings. trends and new generations of coatings.Frontiers in bioengineering and biotechnology · 2022
    Review
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shiho SugawaraDepartment of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, United States of America.
Masahiko MaenoDepartment of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, United States of America.
Cliff LeeDepartment of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, United States of America.
Shigemi NagaiDepartment of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, United States of America.
David M KimDepartment of Oral Medicine, Infection and Immunity, Harvard School of Dental Medicine, Boston, Massachusetts, United States of America.
John Da SilvaDepartment of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, United States of America.
Masazumi NagaiDepartment of Oral Medicine, Infection and Immunity, Harvard School of Dental Medicine, Boston, Massachusetts, United States of America.ORCID http://orcid.org/0000-0002-1414-1950
Hisatomo KondoDepartment of Prosthodontics and Oral Implantology, Iwate Medical University, School of Dental Medicine, Morioka, Iwate, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to produce epithelial attachment on a typical implant abutment surface of smooth titanium. A challenging complication that hinders the success of dental implants is peri-implantitis. A common cause of peri-implantitis may results from the lack of epithelial sealing at the peri-implant collar. Histologically, epithelial sealing is recognized as the attachment of the basement membrane (BM). BM-attachment is promoted by activated platelet aggregates at surgical wound sites. On the other hand, platelets did not aggregate on smooth titanium, the surface typical of the implant abutment. We then hypothesized that epithelial BM-attachment was produced when titanium surface was modified to allow platelet aggregation. Titanium surfaces were coated with a protease activated receptor 4-activating peptide (PAR4-AP). PAR4-AP coating yielded rapid aggregation of platelets on the titanium surface. Platelet aggregates released robust amount of epithelial chemoattractants (IGF-I, TGF-β) and growth factors (EGF, VEGF) on the titanium surface. Human gingival epithelial cells, when they were co-cultured on the platelet aggregates, successfully attached to the PAR4-AP coated titanium surface with spread laminin5 positive BM and consecutive staining of the epithelial tight junction component ZO1, indicating the formation of complete epithelial sheet. These in-vitro results indicate the establishment of epithelial BM-attachment to the titanium surface.

Indexed as

Blood PlateletsCell AdhesionCell Adhesion MoleculesCells, CulturedCoated Materials, BiocompatibleCytokinesDental ImplantsEpithelial CellsGingivaHumansImmunohistochemistryKalininMicroscopy, Electron, ScanningPeptidesPlatelet ActivationPlatelet AggregationCell Adhesion MoleculesCoated Materials, BiocompatibleCytokinesDental ImplantsKalininPeptidesprotease-activated receptor 4Receptors, ThrombinTitaniumZonula Occludens-1 Protein

Identifiers

PMID27741287
PMCPMC5065151

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.