Evidence map›Paper›PMID 27739487›Full record

ArticleScientific reports2016

Small Diameter Blood Vessels Bioengineered From Human Adipose-derived Stem Cells.

Renpeng Zhou, Lei Zhu, Shibo Fu, Yunliang Qian, Danru Wang, Chen Wang

RetractedOpen access · goldAbstract readRetracted Publication
In one paragraph

Article in Scientific reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Adipose Stem Cell Translational Applications: From Bench-to-Bedside.International journal of molecular sciences · 2018
    Review
  7. Review
  8. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Renpeng ZhouDepartment of Plastic and Reconstructive Surgery, Shanghai 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, 639 Zhi Zao Ju Road, Shanghai, 200011 P.R. China.
Lei ZhuDepartment of Plastic &Cosmetic Surgery &Burn, The Third Affiliated Hospital of Sun Yat-sen University, 600 Tian He Road, Guangzhou, 510000, P.R. China.
Shibo FuDepartment of Plastic and Reconstructive Surgery, Shanghai 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, 639 Zhi Zao Ju Road, Shanghai, 200011 P.R. China.
Yunliang QianDepartment of Plastic and Reconstructive Surgery, Shanghai 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, 639 Zhi Zao Ju Road, Shanghai, 200011 P.R. China.
Danru WangDepartment of Plastic and Reconstructive Surgery, Shanghai 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, 639 Zhi Zao Ju Road, Shanghai, 200011 P.R. China.
Chen WangDepartment of Plastic and Reconstructive Surgery, Shanghai 9th People's Hospital, Shanghai Jiao Tong University School of Medicine, 639 Zhi Zao Ju Road, Shanghai, 200011 P.R. China.
Shanghai Jiao Tong University · CNThird Affiliated Hospital of Sun Yat-sen University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Bioengineering of small-diameter blood vessels offers a promising approach to reduce the morbidity associated with coronary artery and peripheral vascular disease. The aim of this study was to construct a two-layered small-diameter blood vessel using smooth muscle cells (SMCs) and endothelial cells (ECs) differentiated from human adipose-derived stem cells (hASCs). The outer layer was constructed with biodegradable polycaprolactone (PCL)-gelatin mesh seeded with SMCs, and this complex was then rolled around a silicone tube under pulsatile stimulation. After incubation for 6 to 8 weeks, the PCL-gelatin degraded and the luminal supporting silicone tube was removed. The smooth muscle layer was subsequently lined with ECs differentiated from hASCs after stimulation with VEGF and BMP4 in combination hypoxia. The phenotype of differentiated SMCs and ECs, and the cytotoxicity of the scaffold and biomechanical assessment were analyzed. Our results demonstrated that the two-layered bioengineered vessels exhibited biomechanical properties similar to normal human saphenous veins (HSV). Therefore, hASCs provide SMCs and ECs for bioengineering of small-diameter blood vessels.

Indexed as

Adipose TissueAdult Stem CellsBlood VesselsBone Morphogenetic Protein 4Cell DifferentiationCells, CulturedEndothelial CellsGelatinHumansMyocytes, Smooth MusclePolyestersTissue EngineeringTissue ScaffoldsVascular Endothelial Growth Factor ABone Morphogenetic Protein 4GelatinpolycaprolactonePolyestersVascular Endothelial Growth Factor A

Identifiers

PMID27739487
PMCPMC5064394
OpenAlexW2530302793

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked