Evidence map›Paper›PMID 27724910›Full record

ArticleBiomedical engineering online2016

Hemodynamic numerical simulations of the disturbance due to intracoronary flow measurements by a Doppler guide wire.

Kamil J Chodzyński, Simone Gremmo, Omer F Eker, Jacques Lalmand, Adel Aminian, Daniel Ribeiro de Sousa, Karim Zouaoui Boudjeltia, Grégory Coussement

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 82% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Kamil J ChodzyńskiLaboratoire de Médecine Expérimentale (ULB 222 Unit), Route de Gozée 706, 6110, Montigny-le-Tilleul, Belgium. Kamil.Chodzynski@umons.ac.be.
Simone GremmoFaculté Polytechnique de Mons-Service Fluides-Machines, Université de Mons, 53, rue du Joncquois, 7000, Mons, Belgium.
Omer F EkerService de Neuroradiologie Hôpital Gui de Chauliac, 80 Avenue Augustin Flich, 34295, Montpellier cedex 05, France.
Jacques LalmandService of Cardiology, CHU Charleroi, Boulevard Zoé Drion, 16000, Charleroi, Belgium.
Adel AminianService of Cardiology, CHU Charleroi, Boulevard Zoé Drion, 16000, Charleroi, Belgium.
Daniel Ribeiro de SousaLaboratoire de Médecine Expérimentale (ULB 222 Unit), Route de Gozée 706, 6110, Montigny-le-Tilleul, Belgium.
Karim Zouaoui BoudjeltiaLaboratoire de Médecine Expérimentale (ULB 222 Unit), Route de Gozée 706, 6110, Montigny-le-Tilleul, Belgium.
Grégory CoussementFaculté Polytechnique de Mons-Service Fluides-Machines, Université de Mons, 53, rue du Joncquois, 7000, Mons, Belgium.
Grand Charleroi Hospital · BEUniversity of Mons · BEHôpital Gui de Chauliac · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSince hemodynamics plays a key role in the development and evolution of cardiovascular pathologies, physician's decision must be based on proper monitoring of relevant physiological flow quantities.

methodsA numerical analysis of the error introduced by an intravascular Doppler guide wire on the peak velocity measurements has been carried out. The effect of probe misalignment (±10°) with respect to the vessel axis was investigated. Numerical simulations were performed on a realistic 3D geometry, reconstructed from coronary angiography images. Furthermore, instead of using Poiseuille or Womersley approximations, the unsteady pulsatile inlet boundary condition has been calculated from experimental peak-velocity measurements inside the vessel through a new approach based on an iterative Newton's algorithm.

resultsThe results show that the presence of the guide modifies significantly both the maximum velocity and the peak position in the section plane; the difference is between 6 and 17 % of the maximum measured velocity depending on the distance from the probe tip and the instantaneous vessel flow rate. Furthermore, a misalignment of the probe may lead to a wrong estimation of the peak velocity with an error up to 10 % depending on the probe orientation angle.

conclusionsThe Doppler probe does affect the maximum velocity and its position during intravascular Doppler measurements. Moreover, the Doppler-probe-wire sampling volume at 5.2 and 10 mm far from the probe tip is not sufficient to prevent its influence on the measurement. This should be taken into account in clinical practice by physicians during intravascular Doppler quantification. The new numerical approach used in this work could potentially be helpful in future numerical simulations to set plausible inlet boundary conditions.

Indexed as

HemodynamicsModels, CardiovascularAlgorithmsCoronary AngiographyCoronary VesselsHydrodynamicsImaging, Three-DimensionalPulse Wave AnalysisDoppler guide wireFlow disturbanceNumerical simulationsUnsteady pulsatile inlet boundary condition

Identifiers

PMID27724910
PMCPMC5490210
OpenAlexW2531603242

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.