Evidence map›Paper›PMID 27711116›Full record

ArticlePloS one2016

Pressure Infusion Cuff and Blood Warmer during Massive Transfusion: An Experimental Study About Hemolysis and Hypothermia.

Thomas G Poder, Denise Pruneau, Josée Dorval, Louis Thibault, Jean-François Fisette, Suzanne K Bédard, Annie Jacques, Patrice Beauregard

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Transfusion strategies for neonates: current perspectives.Annals of medicine and surgery (2012) · 2024
    Review
  3. Article
  4. Experiences of Using Cochrane Systematic Reviews by Local HTA Units.International journal of health policy and management · 2022
    Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Thomas G PoderUETMIS, CIUSSS de l'Estrie-CHUS, Sherbrooke, Québec, Canada, J1G 2E8.ORCID http://orcid.org/0000-0001-7017-096X
Denise PruneauBlood Bank, CIUSSS de l'Estrie-CHUS, Sherbrooke, Québec, Canada, J1H 5N4.
Josée DorvalBlood Bank, CIUSSS de l'Estrie-CHUS, Sherbrooke, Québec, Canada, J1H 5N4.
Louis ThibaultResearch and Development division, Héma-Québec, Québec, Québec, Canada, G1V 5C3.
Jean-François FisetteUETMIS, CIUSSS de l'Estrie-CHUS, Sherbrooke, Québec, Canada, J1G 2E8.
Suzanne K BédardUETMIS, CIUSSS de l'Estrie-CHUS, Sherbrooke, Québec, Canada, J1G 2E8.
Annie JacquesResearch and Development division, Héma-Québec, Québec, Québec, Canada, G1V 5C3.
Patrice BeauregardBlood Bank, CIUSSS de l'Estrie-CHUS, Sherbrooke, Québec, Canada, J1H 5N4.
Centre Hospitalier Universitaire de Sherbrooke · CAHéma-Québec · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBlood warmers were developed to reduce the risk of hypothermia associated with the infusion of cold blood products. During massive transfusion, these devices are used with compression sleeve, which induce a major stress to red blood cells. In this setting, the combination of blood warmer and compression sleeve could generate hemolysis and harm the patient. We conducted this study to compare the impact of different pressure rates on the hemolysis of packed red blood cells and on the outlet temperature when a blood warmer set at 41.5°C is used.

methodsPressure rates tested were 150 and 300 mmHg. Ten packed red blood cells units were provided by Héma-Québec and each unit was sequentially tested.

resultsWe found no increase in hemolysis either at 150 or 300 mmHg. By cons, we found that the blood warmer was not effective at warming the red blood cells at the specified temperature. At 150 mmHg, the outlet temperature reached 37.1°C and at 300 mmHg, the temperature was 33.7°C.

conclusionTo use a blood warmer set at 41.5°C in conjunction with a compression sleeve at 150 or 300 mmHg does not generate hemolysis. At 300 mmHg a blood warmer set at 41.5°C does not totally avoid a risk of hypothermia.

Indexed as

HemolysisPressureTemperatureTransfusion ReactionBlood TransfusionHypothermia

Identifiers

PMID27711116
PMCPMC5053533
OpenAlexW2529459343

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.