Evidence map›Paper›PMID 27696628›Full record

Trial reportNeurogastroenterology and motility2017

Reproducibility of high-definition (3D) manometry and its agreement with high-resolution (2D) manometry in women with fecal incontinence.

S Chakraborty, K J Feuerhak, A R Zinsmeister, A E Bharucha

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Neurogastroenterology and motility, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Observational
  8. Article
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

S ChakrabortyClinical and Enteric Neuroscience Translational and Epidemiological Research Program (C.E.N.T.E.R.), Mayo Clinic, Rochester, MN, USA.
K J FeuerhakClinical and Enteric Neuroscience Translational and Epidemiological Research Program (C.E.N.T.E.R.), Mayo Clinic, Rochester, MN, USA.
A R ZinsmeisterDivision of Biomedical Statistics and Informatics, Department of Health Sciences Research, Mayo Clinic, Rochester, MN, USA.
A E BharuchaClinical and Enteric Neuroscience Translational and Epidemiological Research Program (C.E.N.T.E.R.), Mayo Clinic, Rochester, MN, USA.

Funding

Mayo Clinic Center for Translational Science ActivitiesUL1TR000135 · NCATS · MAYO CLINIC ROCHESTER · PI KHOSLA, SUNDEEP · 2012 to 2015
$41.2M
Pathophysiology of Anorectal DisordersR01DK078924 · NIDDK · MAYO CLINIC ROCHESTER · PI BHARUCHA, ADIL E. · 2008 to 2023
$5.0M
NCATS NIH HHS UL1 TR000135NIDDK NIH HHS R01 DK078924
6 · The paper itself

Abstract

backgroundWhile widely used in clinical practice, the reproducibility of high-definition anorectal manometry (HD-ARM) remains unclear. We evaluated the intra-individual reproducibility of HD-ARM and compared pressures measured with HD-ARM and high-resolution anorectal manometry (HR-ARM).

methodsThirty-six women with fecal incontinence had an initial HD-ARM (HD-ARM1); on the same day, after randomization, 21 had a second (HD-ARM2). Sixteen women had a third (HD-ARM3) 4 weeks later. Twenty-five had also been evaluated by HR-ARM previously. Rectoanal pressures were assessed at rest, during squeeze and simulated evacuation. Concordance among pressures was assessed with Lin's concordance correlation coefficient (CCC). KEY

resultsAnal resting and squeeze pressures measured with HD-ARM were reproducible on the same and different days; for average resting pressures of HD-ARM1 vs HD-ARM2, CCC = 0.73 (95% confidence interval [CI]: 0.53-0.94), and for HD-ARM1 vs HD-ARM3, CCC = 0.60 (95% CI: 0.28-0.93). For maximum squeeze pressures of HD-ARM1 vs HD-ARM2, CCC = 0.86 (95% CI: 0.75-0.97), and for HD-ARM1 vs HD-ARM3, CCC = 0.56 (95% CI: 0.21-0.91). The rectoanal gradient during evacuation was significantly concordant between HD-ARM1 and HD-ARM2 but not HD-ARM1 and HD-ARM3. Resting (CCC = 0.38 [95% CI: 0.14-0.62]) and squeeze pressures (CCC = 0.73 [95% CI: 0.57-0.89]) measured with HD-ARM1 and HR-ARM were also concordant. CONCLUSIONS & INFERENCES: Among women with fecal incontinence, measurements with HD-ARM were reproducible on the same (anal resting and squeeze pressures and rectoanal gradient during evacuation) and different days (anal resting and squeeze pressures) and correlated with HR-ARM measurements. These findings support use of HD-ARM and HR-ARM for longitudinal assessments of anal resting and squeeze pressures.

Indexed as

AgedAnal CanalDouble-Blind MethodFecal IncontinenceFemaleHumansManometryMiddle AgedProspective StudiesReproducibility of Resultsanorectalfecal incontinencehigh definitionhigh resolutionmanometryreproducibility

Identifiers

PMID27696628
PMCPMC5329128

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.