Evidence map›Paper›PMID 27694852›Full record

ArticleScientific reports2016

Pulled microcapillary tube resonators with electrical readout for mass sensing applications.

Donghyuk Lee, Joonhui Kim, Nam-Joon Cho, Taewook Kang, Sangken Kauh, Jungchul Lee

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.5field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Donghyuk LeeSchool of Mechanical and Aerospace Engineering, Seoul National University, Seoul, 08826, Korea.
Joonhui KimSchool of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore.
Nam-Joon ChoSchool of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore.
Taewook KangDepartment of Chemical and Biomolecular Engineering, Sogang University, Seoul, 04107, Korea.
Sangken KauhSchool of Mechanical and Aerospace Engineering, Seoul National University, Seoul, 08826, Korea.
Jungchul LeeDepartment of Mechanical Engineering, Sogang University, Seoul, 04107, Korea.
Nanyang Technological University · SGSeoul National University · KRSogang University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper reports a microfabrication-free approach to make hollow channel mass sensors by pulling a glass capillary and suspending it on top of a machined jig. A part of the pulled section makes simple contact with an actuation node and a quartz tuning fork (QTF) which acts as a sensing node. The two nodes define a pulled micro capillary tube resonator (PμTR) simply supported at two contacts. While a piezo actuator beneath the actuation node excites the PμTR, the QTF senses the resonance frequency of the PμTR. The proposed concept was validated by electrical and optical measurements of resonant spectra of PμTR. Then, different liquid samples including water, ethanol, glycerol, and their binary mixtures were introduced into the PμTR and the resonance frequency of the PμTR was measured as a function of liquid density. Density responsivity of -3,088 Hz-g