Evidence map›Paper›PMID 27686222›Full record

ArticleJournal of medical systems2016

Processing Time Reduction: an Application in Living Human High-Resolution Diffusion Magnetic Resonance Imaging Data.

Nicolás F Lori, Augustin Ibañez, Rui Lavrador, Lucia Fonseca, Carlos Santos, Rui Travasso, Artur Pereira, Rosaldo Rossetti, Nuno Sousa, Victor Alves

Erratum issuedOpen access · bronzeAbstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Stroke mimic diagnoses presenting to a hyperacute stroke unit.Clinical medicine (London, England) · 2017
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors at 6 institutions in 6 countries.

Nicolás F LoriAlgoritmi Centre, University of Minho, Braga, Portugal. Nicolas.Lori@algoritmi.uminho.pt.
Augustin IbañezLaboratory of Experimental Psychology and Neuroscience (LPEN), Institute of Translational and Cognitive Neuroscience (INCyT), INECO Foundation, Favaloro University, Buenos Aires, Argentina.
Rui LavradorInstitute for Biomedical Imaging and Life Sciences (IBILI), Faculty of Medicine, University of Coimbra, Coimbra, Portugal.
Lucia FonsecaCenter for Physics Computation (CFC), Faculty of Science and Technology, University of Coimbra, Coimbra, Portugal.
Carlos SantosInstitute for Biomedical Imaging and Life Sciences (IBILI), Faculty of Medicine, University of Coimbra, Coimbra, Portugal.
Rui TravassoInstitute for Biomedical Imaging and Life Sciences (IBILI), Faculty of Medicine, University of Coimbra, Coimbra, Portugal.
Artur PereiraIETTA, University of Aveiro, Aveiro, Portugal.
Rosaldo RossettiLIAC, University of Porto, Porto, Portugal.
Nuno Sousa3B's, University of Minho, Braga, Portugal.
Victor AlvesAlgoritmi Centre, University of Minho, Braga, Portugal.
University of Coimbra · PTUniversity of Minho · PTAdolfo Ibáñez University · CLMaastricht University · NLUniversidade do Porto · PTUniversity of Aveiro · PT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High Angular Resolution Diffusion Imaging (HARDI) is a type of brain imaging that collects a very large amount of data, and if many subjects are considered then it amounts to a big data framework (e.g., the human connectome project has 20 Terabytes of data). HARDI is also becoming increasingly relevant for clinical settings (e.g., detecting early cerebral ischemic changes in acute stroke, and in pre-clinical assessment of white matter-WM anatomy using tractography). Thus, this method is becoming a routine assessment in clinical settings. In such settings, the computation time is critical, and finding forms of reducing the processing time in high computation processes such as Diffusion Spectrum Imaging (DSI), a form of HARDI data, is very relevant to increase data-processing speed. Here we analyze a method for reducing the computation time of the dMRI-based axonal orientation distribution function h by using Monte Carlo sampling-based methods for voxel selection. Results evidenced a robust reduction in required data sampling of about 50 % without losing signal's quality. Moreover, we show that the convergence to the correct value in this type of Monte Carlo HARDI/DSI data-processing has a linear improvement in data-processing speed of the ODF determination. Although further improvements are needed, our results represent a promissory step for future processing time reduction in big data.

Indexed as

BrainDiffusion Magnetic Resonance ImagingHumansImage Processing, Computer-AssistedMonte Carlo MethodAxonal ODFDiffusion MRIMonte Carlo sampling methodsOptimizationWhite matter

Identifiers

PMID27686222
OpenAlexW2525417049

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.