ArticleJournal of computer assisted tomography2017

Noise Power Characteristics of a Micro-Computed Tomography System.

Muhammad U Ghani, Liqiang Ren, Molly Wong, Yuhua Li, Bin Zheng, Xiujiang John Rong, Kai Yang, Hong Liu

Abstract read
In one paragraph

Article in Journal of computer assisted tomography, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Image quality assessment of a photon counting detector in x-ray projection imaging.Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment · 2019
    Article
  5. Tutorial on X-ray photon counting detector characterization.Journal of X-ray science and technology · 2018
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Muhammad U GhaniFrom the *Center for Biomedical Engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK; †Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX; and ‡Department of Radiation, Massachusetts General Hospital, Boston, MA.
Liqiang Ren
Molly Wong
Yuhua Li
Bin Zheng
Xiujiang John Rong
Kai Yang
Hong Liu

Funding

Clinical Translation of High Energy Phase-Sensitive X-ray Breast TomosynthesisR01CA193378 · NCI · UNIVERSITY OF OKLAHOMA · PI FAJARDO, LAURIE L, JING, ZHENXUE · 2015 to 2019
$3.0M
NCI NIH HHS R01 CA193378
6 · The paper itself

Abstract

objectiveThe aim of this study was to investigate the noise power properties of a micro-computed tomography (micro-CT) system under different operating conditions.

methodsA commercial micro-CT was used in the study that used a flat panel detector with a 127-μm-pixel pitch and a micro-focus x-ray tube. Conical tubes of various diameters were used under different acquisition conditions. Multidimensional noise power spectrums were used as a metric to investigate the noise properties of the system. Noise power spectrum was calculated from the difference data generated by subtraction of 2 identical scans. The noise properties with respect to various parameters that include the impact of number of projections, x-ray spectra, milliampere-second, slice location, object diameter, voxel size, geometric magnification (M), back-projection filters, and reconstruction magnification (Mrecon) were studied.

resultsAt a same isocentric exposure rate of 270 mR/s, the noise power was much lower for the image reconstructed with 3672 views (122 seconds) as compared with the 511 views (17 seconds), whereas at a fixed isocentric exposure of 4600 mR, the noise power levels were almost similar. Image noise with a 50-kV beam was higher as compared with the 90-kV beam at a same isocentric exposure. Image noise from a 16-mm-diameter conical tube was much lower as compared with the 28- and 56-mm tubes under identical isocentric exposures. The choice of back-projection filter influences noise power spectrum curves in terms of width and amplitudes. Reconstruction magnification applied during the reconstruction process increased the noise power at lower spatial frequencies but reduced the noise power at higher spatial frequencies. It can be established that, for small details corresponding to high spatial frequencies, reconstruction magnification can provide an improved signal-to-noise ratio. At all spatial frequencies, the in-plane images had lower noise power levels as compared with the z-plane images.

conclusionsThe noise power properties investigated in this study provide important image quality references for refined cone beam system development, optimization, and operations.

Indexed as

AnimalsCone-Beam Computed TomographyEquipment DesignEquipment Failure AnalysisMiniaturizationPhantoms, ImagingRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsSensitivity and SpecificitySignal-To-Noise Ratio

Identifiers

PMID27680419
PMCPMC5233553

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.