Evidence map›Paper›PMID 27679446›Full record

ArticleAnnals of biomedical engineering2017

Development of a Smart Pump for Monitoring and Controlling Intraocular Pressure.

Simon A Bello, Sharad Malavade, Christopher L Passaglia

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Modeling complex age-related eye disease.Progress in retinal and eye research · 2024
    Review
  2. Accurate Robotic Posterior Capsule Polishing with Tissue Stabilization.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2024
    Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Aqueous Humor Dynamics of the Brown-Norway Rat.Investigative ophthalmology & visual science · 2018
    Article
  11. Biodegradable Piezoelectric Force Sensor.Proceedings of the National Academy of Sciences of the United States of America · 2018
    Article
  12. Article
  13. Review
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Simon A BelloDepartment of Chemical & Biomedical Engineering, University of South Florida, 4202 E Fowler Ave, Tampa, FL, 33620, USA.
Sharad MalavadeDepartment of Ophthalmology, University of South Florida, Tampa, FL, 33620, USA.
Christopher L PassagliaDepartment of Chemical & Biomedical Engineering, University of South Florida, 4202 E Fowler Ave, Tampa, FL, 33620, USA. passaglia@usf.edu.

Funding

A novel method of glaucoma induction and regulationR21EY023376 · NEI · UNIVERSITY OF SOUTH FLORIDA · PI PASSAGLIA, CHRISTOPHER L · 2014 to 2015
$385k
NEI NIH HHS R21 EY023376
6 · The paper itself

Abstract

Animal models of ocular hypertension are important for glaucoma research but come with experimental costs. Available methods of intraocular pressure (IOP) elevation are not always successful, the amplitude and time course of IOP changes are unpredictable and irreversible, and IOP measurement by tonometry is laborious. Here we present a novel system for monitoring and controlling IOP without these limitations. It consists of a cannula implanted in the anterior chamber of the eye, a pressure sensor that continually measures IOP, and a bidirectional pump driven by control circuitry that can infuse or withdraw fluid to hold IOP at user-desired levels. A portable version was developed for tethered use on rats. We show that rat eyes can be cannulated for months without causing significant anatomical or physiological damage although the animal and its eyes freely move. We show that the system measures IOP with <0.7 mmHg resolution and <0.3 mmHg/month drift and can maintain IOP within a user-specified window of desired levels for any duration necessary. We conclude that the system is ready for cage- or bench-side applications. The results lay the foundation for an implantable version that would give glaucoma researchers unprecedented knowledge and control of IOP in rats and potentially larger animals.

Indexed as

Infusion Pumps, ImplantableIntraocular PressureAnimalsGlaucomaRatsClosed loop controlEyeGlaucomaImplantRatTelemetry

Identifiers

PMID27679446
PMCPMC5364042

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.