Evidence map›Paper›PMID 27669571›Full record

ArticlePloS one

Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection.

Thibault Caspar, Anthony Schultz, Mickaël Schaeffer, Aïssam Labani, Mi-Young Jeung, Paul Thomas Jurgens, Soraya El Ghannudi, Catherine Roy, Mickaël Ohana

Open access · goldAbstract read
In one paragraph

Article in PloS one. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Thibault CasparCardiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France.
Anthony SchultzRadiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France.
Mickaël SchaefferPublic Health and Biostatistics Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France.
Aïssam LabaniRadiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France.
Mi-Young JeungRadiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France.
Paul Thomas JurgensUniversity of Colorado, Denver, Colorado, United States of America.
Soraya El GhannudiRadiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France.
Catherine RoyRadiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France.
Mickaël OhanaRadiology Department, Nouvel Hôpital Civil, Strasbourg University Hospital, Strasbourg, France.
Hôpitaux Universitaires de Strasbourg · FRHôpital Civil, Strasbourg · FRUniversité de Strasbourg · FRUniversity of Colorado Denver · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo compare cine MR b-TFE sequences acquired before and after gadolinium injection, on a 3T scanner with a parallel RF transmission technique in order to potentially improve scanning time efficiency when evaluating LV function.

methods25 consecutive patients scheduled for a cardiac MRI were prospectively included and had their b-TFE cine sequences acquired before and right after gadobutrol injection. Images were assessed qualitatively (overall image quality, LV edge sharpness, artifacts and LV wall motion) and quantitatively with measurement of LVEF, LV mass, and telediastolic volume and contrast-to-noise ratio (CNR) between the myocardium and the cardiac chamber. Statistical analysis was conducted using a Bayesian paradigm.

resultsNo difference was found before or after injection for the LVEF, LV mass and telediastolic volume evaluations. Overall image quality and CNR were significantly lower after injection (estimated coefficient cine after > cine before gadolinium: -1.75 CI = [-3.78;-0.0305], prob(coef>0) = 0% and -0.23 CI = [-0.49;0.04], prob(coef>0) = 4%) respectively), but this decrease did not affect the visual assessment of LV wall motion (cine after > cine before gadolinium: -1.46 CI = [-4.72;1.13], prob(coef>0) = 15%).

conclusionsIn 3T cardiac MRI acquired with parallel RF transmission technique, qualitative and quantitative assessment of LV function can reliably be performed with cine sequences acquired after gadolinium injection, despite a significant decrease in the CNR and the overall image quality.

Identifiers

PMID27669571
PMCPMC5036819
OpenAlexW2524132301

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.