Evidence map›Paper›PMID 27669267›Full record

ArticleSensors (Basel, Switzerland)2016

A Human Serum-Based Enzyme-Free Continuous Glucose Monitoring Technique Using a Needle-Type Bio-Layer Interference Sensor.

Dongmin Seo, Sung-Ho Paek, Sangwoo Oh, Sungkyu Seo, Se-Hwan Paek

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Label-Free Optical Resonator-Based Biosensors.Sensors (Basel, Switzerland) · 2020
    Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Dongmin SeoDepartment of Electronics and Information Engineering, Korea University, Sejong 30019, Korea. ehdals20907@korea.ac.kr.
Sung-Ho PaekDepartment of Biological Systems Engineering, Virginia Tech, Blacksburg, VA 24061, USA. paek@vt.edu.
Sangwoo OhDepartment of Electronics and Information Engineering, Korea University, Sejong 30019, Korea. swoh@kriso.re.kr.
Sungkyu SeoDepartment of Electronics and Information Engineering, Korea University, Sejong 30019, Korea. sseo@korea.ac.kr.
Se-Hwan PaekDepartment of Biotechnology and Bioinformatics, Korea University, Sejong 30019, Korea. shpaek@korea.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70-200 mg/dL), revealing high system performance for a wide glycemic state range (45-500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting.

Indexed as

bio-layer interferometrycompetitive assaycontinuous glucose monitoringglucose dialysis methodneedle-type sensor

Identifiers

PMID27669267
PMCPMC5087370

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.