A noninvasive swallowing measurement system using a combination of respiratory flow, swallowing sound, and laryngeal motion.
Article in Medical & biological engineering & computing, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 2 syntheses or guidelines pooled it, 59 citations in OpenAlex.
- Respiratory-Swallow Coordination in Individuals with Parkinson's Disease: A Systematic Review and Meta-Analysis.Journal of Parkinson's disease · 2023Pooled it
- Respiratory Phase and Lung Volume Patterns During Swallowing in Healthy Adults: A Systematic Review and Meta-Analysis.Journal of speech, language, and hearing research : JSLHR · 2019Pooled it
- Respiratory-swallowing Measures and the Impact of Bolus Hold in Individuals with Parkinson's Disease.Dysphagia · 2026Article
- Effects of different levels of food on the acoustic characteristics of swallowing sounds in healthy older people.BMC geriatrics · 2026Article
- Automated identification of bolus types in modified barium swallow studies using deep learning: a preliminary study.medRxiv : the preprint server for health sciences · 2026Article
- Validation of automated 5 mL thin liquid swallowing sound segmentation for estimating audio-derived pharyngeal clearance time.Scientific reports · 2026Article
- Collection of the digital data from the neurological examination.NPJ digital medicine · 2025Article
- Efficacy and Safety of "Vacuum Swallowing" Based on a Strong Negative Esophageal Pressure in Healthy Individuals.Dysphagia · 2025Article
- Mastering Vacuum Swallowing to Improve Pharyngeal Bolus Passage by Creating Negative Pressure in the Esophagus: A Case Report of Two Patients.Progress in rehabilitation medicine · 2025Article
- Oropharyngeal swallowing hydrodynamics of thin and mildly thick liquids in an anatomically accurate throat-epiglottis model.Scientific reports · 2024Article
- Novel Approach Combining Shallow Learning and Ensemble Learning for the Automated Detection of Swallowing Sounds in a Clinical Database.Sensors (Basel, Switzerland) · 2024Article
- Article
- Analysis of swallowing in infants and adults using speckle pattern analysis.Scientific reports · 2022Article
- Singing Experience Influences RSST Scores.Healthcare (Basel, Switzerland) · 2022Article
- Characteristics of dysphagia among different lesion sites of stroke: A retrospective study.Frontiers in neuroscience · 2022Article
- Assessment of cough in head and neck cancer patients at risk for dysphagia-An overview.Cancer reports (Hoboken, N.J.) · 2021Review
- Conformable AlN Piezoelectric Sensors as a Non-invasive Approach for Swallowing Disorder Assessment.ACS sensors · 2021Article
- Adaptive capacity of 2- to 5-month-old infants to the flow, shape, and flexibility of different teats during bottle feeding: a cross-sectional study.BMC pediatrics · 2019Article
- Effects of noninvasive ventilation on the coordination between breathing and swallowing in patients with chronic obstructive pulmonary disease.International journal of chronic obstructive pulmonary disease · 2019Article
- Non-invasive quantification of human swallowing using a simple motion tracking system.Scientific reports · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The assessment of swallowing function is important for the prevention of aspiration pneumonia. We developed a new swallowing monitoring system that uses respiratory flow, swallowing sound, and laryngeal motion. We applied this device to 11 healthy volunteers and 10 patients with dysphagia. Videofluoroscopy (VF) was conducted simultaneously with swallowing monitoring using our device. We measured laryngeal rising time (LRT), the time required for the larynx to elevate to the highest position, and laryngeal activation duration (LAD), the duration between the onset of rapid laryngeal elevation and the time when the larynx returned to the lowest position. In addition, we evaluated the coordination between swallowing and breathing. We found that LAD was correlated with a VF-derived parameter, pharyngeal response duration (PRD) in healthy subjects (LAD: 959 ± 259 ms vs. PRD: 1062 ± 149 ms, r = 0.60); however, this correlation was not found in the dysphagia patients. LRT was significantly prolonged in patients (healthy subjects: 320 ± 175 ms vs. PATIENTS: 465 ± 295 ms, P < 0.001, t test). Furthermore, frequency of swallowing immediately after inspiration was significantly increased in patients. Therefore, the new device may facilitate the assessment of some aspects of swallowing dysfunction.