Evidence map›Paper›PMID 27661023›Full record

Trial reportMedicine2016

Randomized clinical trial comparing abluminal biodegradable polymer sirolimus-eluting stents with durable polymer sirolimus-eluting stents: Nine months angiographic and 5-year clinical outcomes.

Haijun Zhang, Xiangfei Wang, Wei Deng, Shenguo Wang, Junbo Ge, Egon Toft

Abstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in Medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Haijun ZhangDepartment of Health Science and Technology, Faculty of Medicine, Aalborg University, Niels, Denmark Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital Key Laboratory of Public Health Safety, Ministry of Education, School of Public Health, Fudan University, Shanghai Institute of Chemistry, Chinese Academy of Sciences, Beijing, China Biomedical Research Center, College of Medicine, Qatar University, Shareh AIJamiaa, Doha, Qatar.
Xiangfei Wang
Wei Deng
Shenguo Wang
Junbo Ge
Egon Toft

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe biodegradable polymer drug-eluting stents (DES) were developed to improve vascular healing. However, further data and longer-term follow-up are needed to confirm safety and efficacy of these stents. This randomized clinical trial aimed to compare safety and efficacy of 2 sirolimus-eluting stents (SES): Cordimax-a novel abluminal biodegradable polymer SES and Cypher Select-a durable polymer SES, at 9 months angiographic and 5-year clinical follow-up.

methodsWe randomized 402 patients with coronary artery disease to percutaneous coronary intervention with Cordimax (n = 202) or Cypher select (n = 200). Angiographic follow-up was performed at 9 months after the index procedure and clinical follow-up annually up to 5 years. The primary endpoint was angiographic in-stent late luminal loss (LLL). Secondary endpoints included angiographic restenosis rate, target vessel revascularization (TVR), and major adverse cardiac events (MACEs; defined as cardiac death, myocardial infarction, or TVR) at 5-year follow-up.

resultsCordimax was noninferior to Cypher select for in-stent LLL (0.25 ± 0.47 vs 0.18 ± 0.49 mm; P = 0.587) and in-stent mean diameter stenosis (22.19 ± 12.21% vs 19.89 ± 10.79%; P = 0.064) at 9 months angiographic follow-up. The MACE rates were not different at 1 year (5.9% vs 4.0%, P = 0.376); however, MACE rates from 2 to 5 years were lower in the Cordimax group (6.8% vs 13.1%; P = 0.039).

conclusionAbluminal biodegradable polymer SES is noninferior to durable polymer SES at 9-month angiographic and 1-year clinical follow-up. However, MACE rates from 2 to 5 years were less in the abluminal biodegradable polymer group.

Indexed as

Drug-Eluting StentsAbsorbable ImplantsAgedCoronary AngiographyCoronary Artery DiseaseCoronary RestenosisDurable Medical EquipmentFemaleFollow-Up StudiesHumansImmunosuppressive AgentsMaleMiddle AgedPercutaneous Coronary InterventionPolymersPostoperative ComplicationsImmunosuppressive AgentsPolymersSirolimus

Identifiers

PMID27661023
PMCPMC5044893

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.