Evidence map›Paper›PMID 27655667›Full record

ArticleJournal of the Royal Society, Interface2016

Cerebellar-inspired algorithm for adaptive control of nonlinear dielectric elastomer-based artificial muscle.

Emma D Wilson, Tareq Assaf, Martin J Pearson, Jonathan M Rossiter, Sean R Anderson, John Porrill, Paul Dean

Open access · hybridAbstract read
In one paragraph

Article in Journal of the Royal Society, Interface, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 33 citations in OpenAlex.

  1. Review
  2. Brain-inspired biomimetic robot control: a review.Frontiers in neurorobotics · 2024
    Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Emma D WilsonSheffield Robotics, University of Sheffield, Sheffield, UK Department of Psychology, University of Sheffield, Sheffield, UK e.wilson@sheffield.ac.uk.ORCID http://orcid.org/0000-0001-9445-8220
Tareq AssafBristol Robotics Laboratory, University of the West of England and University of Bristol, UK.
Martin J PearsonBristol Robotics Laboratory, University of the West of England and University of Bristol, UK.ORCID http://orcid.org/0000-0002-8642-4845
Jonathan M RossiterBristol Robotics Laboratory, University of the West of England and University of Bristol, UK Department of Engineering Mathematics, University of Bristol, Bristol, UK.
Sean R AndersonSheffield Robotics, University of Sheffield, Sheffield, UK Department of Automatic Control and Systems Engineering, University of Sheffield, Sheffield, UK.ORCID http://orcid.org/0000-0002-7452-5681
John PorrillSheffield Robotics, University of Sheffield, Sheffield, UK Department of Psychology, University of Sheffield, Sheffield, UK.
Paul DeanSheffield Robotics, University of Sheffield, Sheffield, UK Department of Psychology, University of Sheffield, Sheffield, UK.ORCID http://orcid.org/0000-0003-3257-620X
University of Sheffield · GBUniversity of the West of England · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electroactive polymer actuators are important for soft robotics, but can be difficult to control because of compliance, creep and nonlinearities. Because biological control mechanisms have evolved to deal with such problems, we investigated whether a control scheme based on the cerebellum would be useful for controlling a nonlinear dielectric elastomer actuator, a class of artificial muscle. The cerebellum was represented by the adaptive filter model, and acted in parallel with a brainstem, an approximate inverse plant model. The recurrent connections between the two allowed for direct use of sensory error to adjust motor commands. Accurate tracking of a displacement command in the actuator's nonlinear range was achieved by either semi-linear basis functions in the cerebellar model or semi-linear functions in the brainstem corresponding to recruitment in biological muscle. In addition, allowing transfer of training between cerebellum and brainstem as has been observed in the vestibulo-ocular reflex prevented the steady increase in cerebellar output otherwise required to deal with creep. The extensibility and relative simplicity of the cerebellar-based adaptive-inverse control scheme suggests that it is a plausible candidate for controlling this type of actuator. Moreover, its performance highlights important features of biological control, particularly nonlinear basis functions, recruitment and transfer of training.

Indexed as

adaptive-inverse controlartificial musclecerebellumnonlinear controlsoft roboticstransfer of training

Identifiers

PMID27655667
PMCPMC5046955
OpenAlexW2522074789

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.