ArticleEndoscopy international open2016
Percutaneous endoscopic gastrostomy (PEG) using a novel large-caliber introducer technique kit: a retrospective analysis.
Article in Endoscopy international open, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 11 citations in OpenAlex.
- Deconstructing the steps of PEG tube insertion using the introducer technique.VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy · 2024Article
- Outcomes of push and pull percutaneous endoscopic gastrostomy placements in 854 patients: A single-center study.JGH open : an open access journal of gastroenterology and hepatology · 2022Article
- Comparison of Pull and Introducer Techniques for Percutaneous Endoscopic Gastrostomy.Journal of multidisciplinary healthcare · 2022Article
- Comparison of Clinical Outcomes Between Surgical Gastrostomy and Percutaneous Endoscopic Gastrostomy with Introducer Technique in Patients with Upper Aerodigestive Malignancies: A Single-Center Analysis.World journal of surgery · 2020Observational
- Percutaneous Endoscopic Gastrostomy in a Patient With Continuous Intrathecal Baclofen Infusion Therapy.Gastroenterology research · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND AND STUDY
aimsPercutaneous endoscopic gastrostomy (PEG) using the introducer technique is not only useful in patients with upper digestive tract stenosis but has been shown to reduce peristomal infection. In this study, we evaluated the safety and utility of a novel large-caliber introducer PEG kit (using 20 Fr size tube) compared with a push kit of similar size. PATIENTS AND
methodsOne hundred and thirty-six patients who received PEG at our hospital between January 2014 and December 2015 were retrospectively analyzed. Baseline characteristics, laboratory biomarkers, hemodynamic changes, postoperative adverse events and clinical outcomes with both kits were compared.
resultsThe new introducer PEG kit was used in 61 patients while the remaining 75 patients received tube placement using a push technique PEG kit. Except for the prevalence of dementia, which was lower in the introducer PEG kit group, baseline characteristics were similar in both groups. Tube placements were 100 % successful with both PEG kits and there were no significant differences in the change of postoperative hemodynamic or laboratory biomarkers. The Introducer PEG kit group experienced fewer incidence of feeding-related aspiration pneumonia (8.2 % vs. 24 %, P = 0.02), lower peristomal infection scores (1.2 vs. 1.6, P < 0.01), shorter postoperative length of stay (16 days vs. 23.7 days, P = 0.01) and fewer deaths at day 60 (3.3 % vs. 16 %, P = 0.02).
conclusionsGastrostomy using the new large-caliber introducer PEG kit is safe and produced non-inferior (with some favourable) results when compared to the push technique using similar size tubes.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.