In one paragraph

Article in Sensors (Basel, Switzerland), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zhan YangJiangsu Key Laboratory for Advanced Robotics, Soochow University, Suzhou 215123, China. yangzhan@suda.edu.cn.
Yaqiong WangJiangsu Key Laboratory for Advanced Robotics, Soochow University, Suzhou 215123, China. 20154229003@stu.suda.edu.cn.
Bin YangSchool of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200072, China. yangbinfree@163.com.
Guanghui LiJiangsu Key Laboratory for Advanced Robotics, Soochow University, Suzhou 215123, China. 15151541352@163.com.
Tao ChenJiangsu Key Laboratory for Advanced Robotics, Soochow University, Suzhou 215123, China. chent@suda.edu.cn.
Masahiro NakajimaDepartment of Micro-Nano Systems Engineering, Nagoya University, Nagoya 464-8603, Japan. nakajima@mein.nagoya-u.ac.jp.
Lining SunJiangsu Key Laboratory for Advanced Robotics, Soochow University, Suzhou 215123, China. lnsun@hit.edu.cn.
Toshio FukudaDepartment of Micro-Nano Systems Engineering, Nagoya University, Nagoya 464-8603, Japan. fukuda@mein.nagoya-u.ac.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Carbon nanotubes (CNT) have been developed in recent decades for nanodevices such as nanoradios, nanogenerators, carbon nanotube field effect transistors (CNTFETs) and so on, indicating that the application of CNTs for nanoscale electronics may play a key role in the development of nanotechnology. Nanorobotics manipulation systems are a promising method for nanodevice construction and assembly. For the purpose of constructing three-dimensional CNTFETs, a nanorobotics manipulation system with 16 DOFs was developed for nanomanipulation of nanometer-scale objects inside the specimen chamber of a scanning electron microscope (SEM). Nanorobotics manipulators are assembled into four units with four DOFs (X-Y-Z-θ) individually. The rotational one is actuated by a picomotor. That means a manipulator has four DOFs including three linear motions in the X, Y, Z directions and a 360-degree rotational one (X-Y-Z-θ stage, θ is along the direction rotating with X or Y axis). Manipulators are actuated by picomotors with better than 30 nm linear resolution and <1 micro-rad rotary resolution. Four vertically installed AFM cantilevers (the axis of the cantilever tip is vertical to the axis of electronic beam of SEM) served as the end-effectors to facilitate the real-time observation of the operations. A series of kinematic derivations of these four manipulators based on the Denavit-Hartenberg (D-H) notation were established. The common working space of the end-effectors is 2.78 mm by 4.39 mm by 6 mm. The manipulation strategy and vision feedback control for multi-manipulators operating inside the SEM chamber were been discussed. Finally, application of the designed nanorobotics manipulation system by successfully testing of the pickup-and-place manipulation of an individual CNT onto four probes was described. The experimental results have shown that carbon nanotubes can be successfully picked up with this nanorobotics manipulation system.

Indexed as

carbon nanotubemechatronics design and developmentnanorobotics manipulationvisual feedback

Identifiers

PMID27649180
PMCPMC5038756

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.