ArticleIEEE robotics and automation letters
Rapid, Reliable Shape Setting of Superelastic Nitinol for Prototyping Robots.
Article in IEEE robotics and automation letters. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed.
- Towards a Nitinol-Based Microfabricated Approach to Repair Long-Gap Esophageal Atresia.Micromachines · 2026Article
- Uncloggable ventriculoperitoneal shunt system for hydrocephalus via an integrated soft robotic device: CLEARS device.Biomedical microdevices · 2025Article
- Review
- Feasibility of a Shape-Memory-Alloy-Actuator System for Modular Acetabular Cups.Bioengineering (Basel, Switzerland) · 2024Article
- Exceeding traditional curvature limits of concentric tube robots through redundancy resolution.The International journal of robotics research · 2024Article
- Low-cost prototyping of nitinol wires/frames using polymeric cores and sacrificial fixtures with application in individualized frames anchoring through the atrial septum.Scientific reports · 2023Article
- Non-Metallic MR-Guided Concentric Tube Robot for Intracerebral Hemorrhage Evacuation.IEEE transactions on bio-medical engineering · 2023Article
- Embolic Agents: Vascular Plugs.Seminars in interventional radiology · 2022Review
- DynaRing: A Patient-Specific Mitral Annuloplasty Ring With Selective Stiffness Segments.Journal of medical devices · 2022Article
- Targeting Epilepsy Through the Foremen Ovale: How Many Helical Needles are Needed?Annals of biomedical engineering · 2022Article
- Plasma Electrolytic Polishing of Nitinol: Investigation of Functional Properties.Materials (Basel, Switzerland) · 2021Article
- Robotic Applications in Orthodontics: Changing the Face of Contemporary Clinical Care.BioMed research international · 2021Review
- Optic Nerve Sheath Fenestration With a Multi-Arm Continuum Robot.IEEE robotics and automation letters · 2020Article
- Mechatronic Design of a Two-Arm Concentric Tube Robot System for Rigid Neuroendoscopy.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2020Article
- Asymptotically Optimal Kinematic Design of Robots using Motion Planning.Autonomous robots · 2019Article
- Toward the Design of Personalized Continuum Surgical Robots.Annals of biomedical engineering · 2018Article
- Design of a Compact Actuation and Control System for Flexible Medical Robots.IEEE robotics and automation letters · 2017Article
- Optimization of Curvilinear Needle Trajectories for Transforamenal Hippocampotomy.Operative neurosurgery (Hagerstown, Md.) · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Shape setting Nitinol tubes and wires in a typical laboratory setting for use in superelastic robots is challenging. Obtaining samples that remain superelastic and exhibit desired precurvatures currently requires many iterations, which is time consuming and consumes a substantial amount of Nitinol. To provide a more accurate and reliable method of shape setting, in this paper we propose an electrical technique that uses Joule heating to attain the necessary shape setting temperatures. The resulting high power heating prevents unintended aging of the material and yields consistent and accurate results for the rapid creation of prototypes. We present a complete algorithm and system together with an experimental analysis of temperature regulation. We experimentally validate the approach on Nitinol tubes that are shape set into planar curves. We also demonstrate the feasibility of creating general space curves by shape setting a helical tube. The system demonstrates a mean absolute temperature error of 10°C.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials