Evidence map›Paper›PMID 27647456›Full record

ArticleRadiation oncology (London, England)2016

Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints.

Lars König, Alexander Derksen, Nils Papenberg, Benjamin Haas

Open access · goldAbstract read
In one paragraph

Article in Radiation oncology (London, England), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.4field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Lars KönigFraunhofer MEVIS, Maria-Goeppert-Str. 3, Lübeck, 23562, Germany. lars.koenig@mevis.fraunhofer.de.ORCID http://orcid.org/0000-0002-3750-9287
Alexander DerksenFraunhofer MEVIS, Maria-Goeppert-Str. 3, Lübeck, 23562, Germany.
Nils PapenbergFraunhofer MEVIS, Maria-Goeppert-Str. 3, Lübeck, 23562, Germany.
Benjamin HaasVarian Medical Systems, Imaging Laboratory GmbH, Täfernstr. 7, Baden, 5405, Switzerland.
Fraunhofer Institute for Digital Medicine · DEVarian Medical Systems (Switzerland) · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDeformable image registration (DIR) is a key component in many radiotherapy applications. However, often resulting deformations are not satisfying, since varying deformation properties of different anatomical regions are not considered. To improve the plausibility of DIR in adaptive radiotherapy in the male pelvic area, this work integrates a local rigidity deformation model into a DIR algorithm.

methodsA DIR framework is extended by constraints, enforcing locally rigid deformation behavior for arbitrary delineated structures. The approach restricts those structures to rigid deformations, while surrounding tissue is still allowed to deform elastically. The algorithm is tested on ten CT/CBCT male pelvis datasets with active rigidity constraints on bones and prostate and compared to the Varian SmartAdapt deformable registration (VSA) on delineations of bladder, prostate and bones.

resultsThe approach with no rigid structures (REG0) obtains an average dice similarity coefficient (DSC) of 0.87 ± 0.06 and a Hausdorff-Distance (HD) of 8.74 ± 5.95 mm. The new approach with rigid bones (REG1) yields a DSC of 0.87 ± 0.07, HD 8.91 ± 5.89 mm. Rigid deformation of bones and prostate (REG2) obtains 0.87 ± 0.06, HD 8.73 ± 6.01 mm, while VSA yields a DSC of 0.86 ± 0.07, HD 10.22 ± 6.62 mm. No deformation grid foldings are observed for REG0 and REG1 in 7 of 10 cases; for REG2 in 8 of 10 cases, with no grid foldings in prostate, an average of 0.08 % in bladder (REG2: no foldings) and 0.01 % inside the body contour. VSA exhibits grid foldings in each case, with an average percentage of 1.81 % for prostate, 1.74 % for bladder and 0.12 % for the body contour. While REG1 and REG2 keep bones rigid, elastic bone deformations are observed with REG0 and VSA. An average runtime of 26.2 s was achieved with REG1; 31.1 s with REG2, compared to 10.5 s with REG0 and 10.7 s with VMS.

conclusionsWith accuracy in the range of VSA, the new approach with constraints delivers physically more plausible deformations in the pelvic area with guaranteed rigidity of arbitrary structures. Although the algorithm uses an advanced deformation model, clinically feasible runtimes are achieved.

Indexed as

AlgorithmsBone and BonesCone-Beam Computed TomographyDatabases, FactualHumansImage Processing, Computer-AssistedMaleProstateProstatic NeoplasmsRadiotherapyRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedUrinary BladderAdaptive radiotherapyCBCTCTDeformable image registrationLocal rigidityProstate cancer

Identifiers

PMID27647456
PMCPMC5029058
OpenAlexW2523642628

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.