Evidence map›Paper›PMID 27625446›Full record

ArticleLung India : official organ of Indian Chest Society

Evaluation of a Mapleson D CPAP system for weaning of mechanical ventilation in pediatric patients.

Miguel Angel Palomero-Rodríguez, Héctor Chozas de Arteaga, Yolanda Laporta Báez, Jesús de Vicente Sánchez, Pascual Sanabria Carretero, Pilar Sánchez Conde, Antonio Pérez Ferrer

Open access · diamondAbstract read
In one paragraph

Article in Lung India : official organ of Indian Chest Society. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Miguel Angel Palomero-RodríguezDepartment of Anesthesiology, Salamanca University Hospital, Salamanca, Spain.
Héctor Chozas de ArteagaDepartment of Medical, Merck, Mostoles University Hospital, Mostoles, Spain.
Yolanda Laporta BáezDepartment of Anesthesiology, Mostoles University Hospital, Mostoles, Spain.
Jesús de Vicente SánchezDepartment of Anesthesiology, La Paz University Hospital, Madrid, Spain.
Pascual Sanabria CarreteroDepartment of Anesthesiology, La Paz University Hospital, Madrid, Spain.
Pilar Sánchez CondeDepartment of Medical, Merck, Mostoles University Hospital, Mostoles, Spain.
Antonio Pérez FerrerDepartment of Anesthesiology, La Paz University Hospital, Madrid, Spain.
Hospital Universitario La Paz · ESHospital Universitario de Móstoles · ESUniversidad de Salamanca · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOver the last years, we have used a flow-inflating bag circuit with a nasotracheal or nasopharyngeal tube as an interface to deliver effective CPAP support in infants ("Mapleson D CPAP system"). The primary goal of this study was to assess the usefulness of the "Mapleson D CPAP system" for weaning of mechanical ventilation (MV) in infants who received MV over 24 h. MATERIALS AND

methodsAll infants who received MV for more than 24 h in the last year were enrolled in the study. Demographic data included age, gender, weight, and admission diagnosis. Heart rate, respiratory rate, blood pressure, and oxygen saturation were measured during MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation. Patients were classified into two groups: patients MV more than 48 h, and patients with MV fewer than 48 h. P < 0.05 was considered statistically significant.

resultsA total of 50 children were enrolled in the study, with a median age was 34 ± 45 months (range, 1-59 months) and median weight was 11.98 ± 9.31 kg (range, 1-48 kg). Median duration of MV was 480 h (range, 2-570). There were no significant differences in PaO2, PaCO2, and pH among MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation and spontaneous ventilation with the nasopharyngeal Mapleson D CPAP system or with nasal prongs. The overall extubation failure rate was 26% (n = 13). Weight and age were significantly associated with extubation failure (P < 0.05).

conclusionsThe Mapleson D CPAP system, in our opinion, is a useful and safe alternative to more complex and expensive noninvasive CPAP and BiPAP weaning from MV in infants.

Indexed as

CPAPnasopharyngeal tubenoninvasive ventilationprolonged ventilationweaning

Identifiers

PMID27625446
PMCPMC5006332
OpenAlexW2510822364

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.