Evidence map›Paper›PMID 27610396›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2016

Development and validation of a segmentation-free polyenergetic algorithm for dynamic perfusion computed tomography.

Yuan Lin, Ehsan Samei

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Yuan LinCarestream Health Inc. , Division of Research and Innovations, 1049 Ridge Road West, Rochester, New York 14615, United States.
Ehsan SameiDuke University , Carl E. Ravin Advanced Imaging Lab, 2424 Erwin Road, Suite 302, Durham, North Carolina 27705, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dynamic perfusion imaging can provide the morphologic details of the scanned organs as well as the dynamic information of blood perfusion. However, due to the polyenergetic property of the x-ray spectra, beam hardening effect results in undesirable artifacts and inaccurate CT values. To address this problem, this study proposes a segmentation-free polyenergetic dynamic perfusion imaging algorithm (pDP) to provide superior perfusion imaging. Dynamic perfusion usually is composed of two phases, i.e., a precontrast phase and a postcontrast phase. In the precontrast phase, the attenuation properties of diverse base materials (e.g., in a thorax perfusion exam, base materials can include lung, fat, breast, soft tissue, bone, and metal implants) can be incorporated to reconstruct artifact-free precontrast images. If patient motions are negligible or can be corrected by registration, the precontrast images can then be employed as a priori information to derive linearized iodine projections from the postcontrast images. With the linearized iodine projections, iodine perfusion maps can be reconstructed directly without the influence of various influential factors, such as iodine location, patient size, x-ray spectrum, and background tissue type. A series of simulations were conducted on a dynamic iodine calibration phantom and a dynamic anthropomorphic thorax phantom to validate the proposed algorithm. The simulations with the dynamic iodine calibration phantom showed that the proposed algorithm could effectively eliminate the beam hardening effect and enable quantitative iodine map reconstruction across various influential factors. The error range of the iodine concentration factors ([Formula: see text]) was reduced from [Formula: see text] for filtered back-projection (FBP) to [Formula: see text] for pDP. The quantitative results of the simulations with the dynamic anthropomorphic thorax phantom indicated that the maximum error of iodine concentrations can be reduced from [Formula: see text] for FBP to less than [Formula: see text] for pDP, which suggested that the proposed algorithm could not only effectively eliminate beam hardening artifacts but also significantly reduce the influence of the metal artifacts and accurately reconstruct the iodine map regardless of the influential factors. A segmentation-free polyenergetic dynamic perfusion imaging algorithm was proposed and validated via simulations. This method can accurately reconstruct artifact-free iodine maps for quantitative analyses.

Indexed as

beam hardeningcomputed tomographydynamic imagingperfusion imagingpolyenergetic

Identifiers

PMID27610396
PMCPMC4994476

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.