Evidence map›Paper›PMID 27610037›Full record

ArticleThe Korean journal of physiology & pharmacology : official journal of the Korean Physiological Society and the Korean Society of Pharmacology2016

Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: an in-silico modeling study.

Jun-Seop Song, Young-Seon Lee, Minki Hwang, Jung-Kee Lee, Changyong Li, Boyoung Joung, Moon-Hyoung Lee, Eun Bo Shim, Hui-Nam Pak

Abstract read
In one paragraph

Article in The Korean journal of physiology & pharmacology : official journal of the Korean Physiological Society and the Korean Society of Pharmacology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. VirtualFrontiers in physiology · 2017
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jun-Seop SongDivision of Cardiology, Yonsei University Health System, Seoul 03722, Korea.
Young-Seon LeeDivision of Cardiology, Yonsei University Health System, Seoul 03722, Korea.
Minki HwangDivision of Cardiology, Yonsei University Health System, Seoul 03722, Korea.
Jung-Kee LeeDivision of Cardiology, Yonsei University Health System, Seoul 03722, Korea.
Changyong LiDivision of Cardiology, Yonsei University Health System, Seoul 03722, Korea.
Boyoung JoungDivision of Cardiology, Yonsei University Health System, Seoul 03722, Korea.
Moon-Hyoung LeeDivision of Cardiology, Yonsei University Health System, Seoul 03722, Korea.
Eun Bo ShimDepartment of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon 24341, Korea.
Hui-Nam PakDivision of Cardiology, Yonsei University Health System, Seoul 03722, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Although 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in-silico left atrium (LA). We conducted this study by importing the heart CT image of a patient with AF into a 3D-homogeneous human LA model. Electrogram morphology, CFAE-cycle lengths (CLs) were compared for 16 different orientations of a virtual bipolar conventional catheter (conv-cath: size 3.5 mm, inter-electrode distance 4.75 mm). Additionally, the spatial correlations of CFAE-CLs and the percentage of consistent sites with CFAE-CL<120 ms were analyzed. The results from the conv-cath were compared with that obtained using a mini catheter (mini-cath: size 1 mm, inter-electrode distance 2.5 mm). Depending on the catheter orientation, the electrogram morphology and CFAE-CLs varied (conv-cath: 11.5±0.7% variation, mini-cath: 7.1±1.2% variation), however the mini-cath produced less variation of CFAE-CL than conv-cath (p<0.001). There were moderate spatial correlations among CFAE-CL measured at 16 orientations (conv-cath: r=0.3055±0.2194 vs. mini-cath: 0.6074±0.0733, p<0.001). Additionally, the ratio of consistent CFAE sites was higher for mini catheter than conventional one (38.3±4.6% vs. 22.3±1.4%, p<0.05). Electrograms and CFAE distribution are affected by catheter orientation and electrode configuration in the in-silico LA model. However, there was moderate spatial consistency of CFAE areas, and narrowly spaced bipolar catheters were less influenced by catheter direction than conventional catheters.

Indexed as

Atrial fibrillationBipolar electrogramComplex fractionated atrial electrogramComputational modeling

Identifiers

PMID27610037
PMCPMC5014997

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.