ReviewIEEE transactions on bio-medical engineering2017
Optical Detection of Ultrasound in Photoacoustic Imaging.
Review in IEEE transactions on bio-medical engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 59 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
59 citing papers in PubMed, 169 citations in OpenAlex.
- Silicon-photonics optoacoustic sensor for fully wearable blood pressure monitoring.Nature communications · 2026Article
- Ultra-sensitive wideband diffraction-grating-coupled-mode Fabry-Pérot resonators for ultrasound and photoacoustic detection.Photoacoustics · 2026Article
- 150 MHz polymer resonator for optoacoustic mesoscopy based on a tapered optical fiber.Nature communications · 2026Article
- Microfiber Interferometric Sensor for Ultrasound Detection.Sensors (Basel, Switzerland) · 2026Article
- Amorphous silicon-carbide photonics for ultrasound imaging.Communications physics · 2026Article
- Wavelength-time-division multiplexed fiber-optic sensor array for wide-field photoacoustic microscopy.Photoacoustics · 2025Article
- Axially multifocal metalens for 3D volumetric photoacoustic imaging of neuromelanin in live brain organoid.Science advances · 2025Article
- Non-iterative model-based inversion for low channel-count optical ultrasound imaginga).The Journal of the Acoustical Society of America · 2024Article
- Bragg grating etalon-based optical fiber for ultrasound and optoacoustic detection.Nature communications · 2024Article
- Perspectives on endoscopic functional photoacoustic microscopy.Applied physics letters · 2024Article
- Ultrasound sensing with optical microcavities.Light, science & applications · 2024Review
- Critical Advances for Democratizing Ultrasound Diagnostics in Human and Veterinary Medicine.Annual review of biomedical engineering · 2024Review
- Photoacoustic viscoelasticity assessment of prefrontal cortex and cerebellum in normal and prenatal valproic acid-exposed rats.Photoacoustics · 2024Article
- High speed innovations in photoacoustic microscopy.Npj imaging · 2024Review
- Optical ultrasound sensors for photoacoustic imaging: a review.Journal of biomedical optics · 2024Review
- Theoretical and experimental study on the detection limit of the micro-ring resonator based ultrasound point detectors.Photoacoustics · 2023Article
- Tailored photoacoustic apertures with superimposed optical holograms.Biomedical optics express · 2023Article
- Broadband transparent ultrasound transducer with polymethyl methacrylate as matching layer forPhotoacoustics · 2023Article
- Silicon photonic acoustic detector (SPADE) using a silicon nitride microring resonator.Photoacoustics · 2023Article
- Highly sensitive ultrasound detection using nanofabricated polymer micro-ring resonators.Nano convergence · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
Abstract
objectivePhotoacoustic (PA) imaging emerges as a unique tool to study biological samples based on optical absorption contrast. In PA imaging, piezoelectric transducers are commonly used to detect laser-induced ultrasonic waves. However, they typically lack adequate broadband sensitivity at ultrasonic frequency higher than 100 MHz, whereas their bulky size and optically opaque nature cause technical difficulties in integrating PA imaging with conventional optical imaging modalities. To overcome these limitations, optical methods of ultrasound detection were developed and shown their unique applications in PA imaging.
methodsWe provide an overview of recent technological advances in optical methods of ultrasound detection and their applications in PA imaging. A general theoretical framework describing sensitivity, bandwidth, and angular responses of optical ultrasound detection is also introduced.
resultsOptical methods of ultrasound detection can provide improved detection angle and sensitivity over significantly extended bandwidth. In addition, its versatile variants also offer additional advantages, such as device miniaturization, optical transparency, mechanical flexibility, minimal electrical/mechanical crosstalk, and potential noncontact PA imaging.
conclusionThe optical ultrasound detection methods discussed in this review and their future evolution may play an important role in PA imaging for biomedical study and clinical diagnosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials