Evidence map›Paper›PMID 27601144›Full record

ArticleLa Radiologia medica2017

Usefulness of paclitaxel-releasing high-pressure balloon associated with cutting balloon angioplasty for treatment of outflow stenoses of failing hemodialysis arteriovenous shunts.

Anna Maria Ierardi, Marco Franchin, Federico Fontana, Gabriele Piffaretti, Ejona Duka, Massimo Tonolini, Vittorio Miele, Matteo Tozzi, Gianpaolo Carrafiello

Abstract read
PubMed Publisher
In one paragraph

Article in La Radiologia medica, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Anna Maria IerardiInterventional Radiology, Department of Radiology, University of Insubria, Viale L. Borri, 57, 21100, Varese (VA), Italy.
Marco FranchinVascular Surgery Department, University of Insubria, Viale L. Borri, 57, 21100, Varese (VA), Italy.
Federico FontanaInterventional Radiology, Department of Radiology, University of Insubria, Viale L. Borri, 57, 21100, Varese (VA), Italy.
Gabriele PiffarettiVascular Surgery Department, University of Insubria, Viale L. Borri, 57, 21100, Varese (VA), Italy.
Ejona DukaInterventional Radiology, Department of Radiology, University of Insubria, Viale L. Borri, 57, 21100, Varese (VA), Italy.
Massimo TonoliniDepartment of Radiology, "Luigi Sacco" University Hospital, Via G.B. Grassi 74, 20157, Milan (MI), Italy.
Vittorio MieleDepartment of Emergency Radiology, S. Camillo Hospital, Circonvallazione Gianicolense, 87, 00152, Rome, Italy.
Matteo TozziVascular Surgery Department, University of Insubria, Viale L. Borri, 57, 21100, Varese (VA), Italy.
Gianpaolo CarrafielloDiagnostic and Interventional Radiology Unit, Department of Health Sciences, University of Milan, Via A. di Rudinì 8, 20142, Milan, Italy. gcarraf@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo evaluate the technical and clinical success, primary patency (PP) and complications of angioplasty performed with paclitaxel-coated balloon (PCBs) associated with cutting balloon and for the treatment of the outflow stenoses of failing hemodialysis arteriovenous shunt. MATERIAL AND

methodsFrom September 2014 to September 2015, 50 patients with 66 stenoses were registered. Vascular accesses were autogenous (n = 20) and prosthetic (n = 30). Stenosis were documented during follow-up with routine echo-color Doppler, clinical evaluation and in the remaining incidentally during fistulography. Angioplasty was performed with cutting balloon and afterward with PCB. The mean follow-up time was 8 months (range 6-15 months). Technical success, clinical success, primary patency and complications were registered.

resultsTechnical success was 100 %. Clinical success was 94.7 %. Primary patency rate was 87.7 %; in five patients, a significant re-stenosis (≥50 %) was registered. A residual asymptomatic stenosis (<30 %) was registered in four cases (7 %). No major complications were registered.

conclusionsA short-term patency benefit may be obtained including PCB in angioplasty treatment of failing hemodialysis arteriovenous shunts.

Indexed as

Angioplasty, BalloonAdultAgedAged, 80 and overArteriovenous Shunt, SurgicalCombined Modality TherapyConstriction, PathologicFemaleGraft Occlusion, VascularHumansMaleMiddle AgedPaclitaxelProspective StudiesRenal DialysisTreatment OutcomePaclitaxelHemodialysis arteriovenous shuntOutflow stenosesPaclitaxel-coated balloon

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.