ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2017
Comparing Steri-Strip and surgical staple wound closures after primary total knee arthroplasties.
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06957444 (Rate of Allergic Contact Dermatitis and Cosmetic Outcomes for Three Wound Closure Techniques in Joint Arthroplasty Patients), which is not on this map. Cited by 8 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Rate of Allergic Contact Dermatitis and Cosmetic Outcomes for Three Wound Closure Techniques in Joint Arthroplasty Patients: A Randomized, Controlled Trial
Who cites it
8 citing papers in PubMed, 2 syntheses or guidelines pooled it, 20 citations in OpenAlex.
- Comparison between Zip-Type Skin Closure Device and Staple for Total Knee Arthroplasty: A Meta-Analysis.BioMed research international · 2021Pooled it
- Skin Closure Tape and Surgical Staples in Primary Total Knee Arthroplasty: A Systematic Review and Meta-Analysis.BioMed research international · 2020Pooled it
- Comparison of Leukosan SkinLink with surgical suture for traumatic laceration repair: A randomized controlled trial.Medicine · 2018Trial
- Clinical outcomes of modified intradermal vs. traditional intermittent suture technique in total knee arthroplasty: a single-center retrospective study.Frontiers in surgery · 2025Article
- Surgical Dressing Cosmesis in the Immediate Postoperative Setting: A Crowdsourcing-based Study.Plastic and reconstructive surgery. Global open · 2025Article
- Skin Adhesive Tapes: An Effective Wound Closure Method for Percutaneous Vertebral Body Stenting.Cureus · 2024Article
- Bridging wounds: tissue adhesives' essential mechanisms, synthesis and characterization, bioinspired adhesives and future perspectives.Burns & trauma · 2022Review
- Multilayer Watertight Closure to Address Adverse Events From Primary Total Knee and Hip Arthroplasty: A Systematic Review of Wound Closure Methods by Tissue Layer.Arthroplasty today · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSteri-Strips (3M, Two Harbors, MN, USA) have recently been employed for skin closures after orthopedic surgeries. Here we compare the performance of Steri-Strips and skin staples for wound closure after primary total knee arthroplasties (TKAs).
methodsA total of 76 consecutive osteoarthritic knees (71 patients) that underwent a primary TKA at our facility were included in this study. Thirty-eight knees received Steri-Strips for wound closure and were evaluated prospectively. The other 38 knees were closed with skin staples (Staple group) and evaluated retrospectively.
resultsNo deep or superficial infections developed in this series. Although Steri-Strips detached from three knees during the 10-day postoperative period, no dehiscence was observed. Thirteen knees developed blisters around the surgical incision in the Steri-Strip group compared with five knees in the Staple group. The average operative time for the Steri-Strip group was 60.6 min (SD 7.3) compared with 54.1 min (SD 6.9) in the Staple group. There were significant differences in operative time (p < 0.001) and tourniquet time (p < 0.001) between the two groups. The average time until patients were permitted to start showering was significantly shorter in the Steri-Strip group (p = 0.0496). The material cost for Steri-Strips was approximately $3.00 USD for one operation compared with $26 USD for skin staplers.
conclusionsWound closure with Steri-Strips after a TKA does not require postoperative material removal and may have improved safety, comfort, cosmesis and cost-effectiveness compared with traditional skin closures. LEVEL OF EVIDENCE: Level II, Prognostic study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials