Evidence map›Paper›PMID 27600235›Full record

ReviewMicroarrays (Basel, Switzerland)2015

Integrated Microfluidic Nucleic Acid Isolation, Isothermal Amplification, and Amplicon Quantification.

Michael G Mauk, Changchun Liu, Jinzhao Song, Haim H Bau

Open access · goldAbstract readReview
In one paragraph

Review in Microarrays (Basel, Switzerland), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Michael G MaukSchool of Engineering and Applied Sciences, University of Pennsylvania, 220 S 33 rd Street, Philadelphia, PA 19104, USA. mmauk@seas.upenn.edu.
Changchun LiuSchool of Engineering and Applied Sciences, University of Pennsylvania, 220 S 33 rd Street, Philadelphia, PA 19104, USA. lchangc@seas.upenn.edu.
Jinzhao SongSchool of Engineering and Applied Sciences, University of Pennsylvania, 220 S 33 rd Street, Philadelphia, PA 19104, USA. songjinz@seas.upenn.edu.
Haim H BauSchool of Engineering and Applied Sciences, University of Pennsylvania, 220 S 33 rd Street, Philadelphia, PA 19104, USA. bau@seas.upenn.edu.
University of Pennsylvania · US

Funding

Point Detection of Pathogens in Oral Samples via UPTU01DE017855 · NIDCR · NEW YORK UNIVERSITY · PI MALAMUD, DANIEL · 2006 to 2010
$7.9M
Fully-Integrated, Non-Instrumented Device for Molecular DiagnosticsK25AI099160 · NIAID · UNIVERSITY OF PENNSYLVANIA · PI LIU, CHANGCHUN · 2012 to 2016
$642k
Point of Care Device for Molecular Detection of HIVR41AI104418 · NIAID · AC DIAGNOSTICS, INC. · PI BAU, HAIM H, XIA, JUN Q · 2013 to 2013
$300k
NIAID NIH HHS K25 AI099160NIAID NIH HHS R41 AI104418NIDCR NIH HHS U01 DE017855
6 · The paper itself

Abstract

Microfluidic components and systems for rapid (<60 min), low-cost, convenient, field-deployable sequence-specific nucleic acid-based amplification tests (NAATs) are described. A microfluidic point-of-care (POC) diagnostics test to quantify HIV viral load from blood samples serves as a representative and instructive example to discuss the technical issues and capabilities of "lab on a chip" NAAT devices. A portable, miniaturized POC NAAT with performance comparable to conventional PCR (polymerase-chain reaction)-based tests in clinical laboratories can be realized with a disposable, palm-sized, plastic microfluidic chip in which: (1) nucleic acids (NAs) are extracted from relatively large (~mL) volume sample lysates using an embedded porous silica glass fiber or cellulose binding phase ("membrane") to capture sample NAs in a flow-through, filtration mode; (2) NAs captured on the membrane are isothermally (~65 °C) amplified; (3) amplicon production is monitored by real-time fluorescence detection, such as with a smartphone CCD camera serving as a low-cost detector; and (4) paraffin-encapsulated, lyophilized reagents for temperature-activated release are pre-stored in the chip. Limits of Detection (LOD) better than 10³ virons/sample can be achieved. A modified chip with conduits hosting a diffusion-mode amplification process provides a simple visual indicator to readily quantify sample NA template. In addition, a companion microfluidic device for extracting plasma from whole blood without a centrifuge, generating cell-free plasma for chip-based molecular diagnostics, is described. Extensions to a myriad of related applications including, for example, food testing, cancer screening, and insect genotyping are briefly surveyed.

Indexed as

isothermal nucleic acid amplificationlab on a chipmicrofluidics

Identifiers

PMID27600235
PMCPMC4996405
OpenAlexW1788994473

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.