Evidence map›Paper›PMID 27599665›Full record

ArticleAnatolian journal of cardiology2017

Transcatheter closure of PDA in premature babies less than 2 kg.

Nazmi Narin, Özge Pamukçu, Ali Baykan, Mustafa Argun, Abdullah Özyurt, Adnan Bayram, Kazım Üzüm

Abstract read
In one paragraph

Article in Anatolian journal of cardiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Article
  3. Observational
  4. Article
  5. Use of the Medtronic Microvascular Plug 7Q for transcatheter closure of large patent ductus arteriosus in infants weighing less than 2.5 kg.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2022
    Article
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nazmi NarinDepartment of Pediatric Cardiology, Faculty of Medicine, Erciyes University; Kayseri-Turkey.
Özge PamukçuDepartment of Pediatric Cardiology, Faculty of Medicine, Erciyes University; Kayseri-Turkey. ozgepamukcu2002@yahoo.com.
Ali BaykanDepartment of Pediatric Cardiology, Faculty of Medicine, Erciyes University; Kayseri-Turkey.
Mustafa ArgunDepartment of Pediatric Cardiology, Faculty of Medicine, Erciyes University; Kayseri-Turkey.
Abdullah ÖzyurtDepartment of Pediatric Cardiology, Faculty of Medicine, Erciyes University; Kayseri-Turkey.
Adnan BayramDepartment of Anesthesiology, Faculty of Medicine, Erciyes University; Kayseri-Turkey.
Kazım ÜzümDepartment of Pediatric Cardiology, Faculty of Medicine, Erciyes University; Kayseri-Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveOur hypothesis was that percutaneous PDA closure in babies less than 2 kg was a safe and effective method. The aim of this study is to share our experience in transcatheter PDA closure in infants whose body weight is less than 2 kg in order to support our hypothesis.

methodsBetween July 1997 and October 2014, 382 percutaneous PDA closures were done in our center. Nineteen patients who weighed less than 2 kg were included in this retrospectively study. The other inclusion criteria were 1) being symptomatic and PDA was thought as a possible contributor of medical state and 2) persistence of PDA after medical closure treatment. Patients who had sepsis and bleeding diathesis were excluded. According to size and shape of PDA, different types of devices were used such as detachable coils and Amplatzer duct occluders. Data was expressed as mean (SD) or median (minimum-maximum). Comparisons of means and medians were performed with Student's t-test and with Mann-Whitney U test, respectively.

resultsThe median patient age and weight were 32 days and 1603 g (range 910-2000 g) respectively. Mean PDA diameter was 3.2±1.3 mm. Morphology of PDA was type A in 7 patients, type C in 10, type E in 1, and type B in 1 patient. There were no reported major complications. Stenosis of left pulmonary artery was detected in four patients, all of which resolved in 6 months follow-up.

conclusionPercutaneous PDA closure in babies less than 2 kg is a safe and effective method that can be an alternative to surgery. Main distinguishing feature of this study is that it includes the largest cohort of patients less than 2 kg whose PDA closed percutaneously.

Indexed as

Infant, PrematureInfant, Very Low Birth WeightCardiac CatheterizationCohort StudiesDuctus Arteriosus, PatentFemaleHumansInfantInfant, NewbornMaleRetrospective StudiesTreatment Outcome

Identifiers

PMID27599665
PMCPMC5336755

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.