ArticleMultidisciplinary respiratory medicine2016
Dry-powder inhalers in patients with persistent airflow limitation: usability and preference.
Article in Multidisciplinary respiratory medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- Improving the Efficiency of Respiratory Drug Delivery: A Review of Current Treatment Trends and Future Strategies for Asthma and Chronic Obstructive Pulmonary Disease.Pulmonary therapy · 2017Review
- Peak inspiratory flow in children and adolescents with asthma using dry powder inhalers: a cross-sectional study.Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e TisilogiaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundInhalation devices represent per sé critical factors because they can affect the therapeutic outcomes independently of the drug used. The role of patients' usability and preference (PUP) for Dry Powder Inhalers (DPIs) is high indeed because they can influence the extent of the adherence to treatment and the therapeutic outcomes. Aim of the study was to assess and compare the PUP of three different DPIs in out-patients with persistent airflow limitation due to asthma or COPD.
methodsThe PUP of three different DPIs (Breezhaler; Genuair; Handihaler) were investigated by means of the Handling Questionnaire in out-patients with persistent airflow limitation needing an inhalation therapy. Patients had to report their preference before and after the nurse's instruction on the handling of each device. The nurse had also to note the critical steps during the patient's procedure for actuation; to count the number of attempts needed for actuating the device properly, and to measure the time (in sec.) required for these procedures. Data were collected up to three attempts per device. STATISTICS: Welch test was used for normal distributed variables, while the Wilcoxon test for not normal distributed variables. The χ (2) test and the ANOVA test were also used. Univariate and multivariate regressions were also performed in order to investigate the effect of patients' characteristics and of technical differences of each device on their proper use.
resultsThree hundred thirty-three consecutive out-patients (age range 55-58 years, and well matched for gender), with persistent airway limitation of different severity were investigated, suffering from bronchial asthma (n = 175) or from chronic obstructive pulmonary disease (COPD) (n = 158). In particular, 127 patients (38 %) tested the three DPIs, while 110 (33 %) tested Breezhaler and Genuair, and 96 (29 %) Breezhaler and Handihaler. More than 50 % of patients who tested all devices preferred the Genuair and perceived this device as the easiest to use. The nurse's judgement confirmed their opinion. When compared to the other two DPIs, Genuair proved the least problematic either according to the patients' judgement and to the nurse's opinion. Mean number of attempts aimed to achieving the first proper actuation was lower with Genuair than with Breezhaler and Handihaler (1.5 vs 2.5-2.6, p < 0.0001). Finally, Genuair also proved the easiest to use and the least problematic according to the nurse judgement (0.0001), the most easily learned (0.0001), and that one with a successful rate of more than 56 % at the first attempt. Breezhaler and Handihaler needed an average of about one additional attempt to be used properly (p < 0.0001), and their usability proved significantly more difficult (OR of successful rate between 0.15 and 0.17, p < 0.001). In general, older patients needed more attempts to perform their first proper inhalation; their successful rate was lower, and they needed more time to learn how to use devices properly: with Genuair these differences were minimized.
conclusionsThe possibility of grading objectively the performance of different DPIs in terms of their usability and therapeutic convenience in daily life represents a crucial operational opportunity to pursue. To note that a substantial discrepancy exists between the patients' belief "at glance" and the patients' effective usability with can be registered with some devices. From a general point of view, devices requiring less manual actions for their actuation confirmed their better usability and proper handling after less attempts. In particular, Genuair came out as the most preferred DPI also when several different aspects of preference and usability are assessed objectively and compared.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.