Evidence map›Paper›PMID 27587605›Full record

Trial reportNephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association2017

Performance of hemodialysis with novel medium cut-off dialyzers.

Alexander H Kirsch, Raphael Lyko, Lars-Göran Nilsson, Werner Beck, Michael Amdahl, Petra Lechner, Andreas Schneider, Christoph Wanner, Alexander R Rosenkranz, Detlef H Krieter

Erratum issued 9 registry-linked trialsOpen access · hybridAbstract readMulticenter StudyRandomized Controlled Trial
In one paragraph

Trial report in Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. It is linked to 9 registered trials, which are not on this map. Cited by 113 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
113citing papers in PubMed, 4 pooled it
15.8field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02377570 nacompletednot on this map

Comparison of the Clinical Performance of 3 THERANOVA 400 Dialyzer Prototypes With a High-Flux Dialyzer in Hemodialysis Mode - A Pilot Study

TypeinterventionalSponsorVantive Health LLCRan2015 to 2015Enrolled20ConditionsEnd Stage Renal DiseaseArmsTHERANOVA 400 dialyzer prototype AA, THERANOVA 400 dialyzer prototype BB, THERNOVA 400 dialyzer prototype CC, FX CorDiax 80 dialyzer
NCT02377622 nacompletednot on this map

Comparison of the Clinical Performance of 2 THERANOVA 400 Dialyzer Prototypes in HD With a High-Flux Dialyzer in HD and a High-Flux Dialyzer in hvHDF - A Pilot Study

TypeinterventionalSponsorVantive Health LLCRan2015 to 2015Enrolled20ConditionsEnd Stage Renal DiseaseArmsTHERANOVA 400 dialyzer prototype AA, THERANOVA 400 dialyzer prototype BB, FX CorDiax 80 Dialyzer, FX CorDiax 800 Dialyzer
NCT03448887 nacompletednot on this mapstarted 2018, after this paper: background citation

Cardiovascular Risk Comparison Between Expanded Hemodialysis Using Theranova and On-line Hemodiafiltration - Exploratory, Multicenter, Randomized Clinical Trial

TypeinterventionalSponsorSeoul National University HospitalRan2018 to 2020Enrolled80ConditionsKidney Failure, Chronic, Renal DialysisArmsTheranova, Online hemodiafiltration
NCT04211571 nacompletednot on this mapstarted 2020, after this paper: background citation

Randomized Controlled Trial of Theranova Versus High-flux Dialyzer on Preservation of REsidual RenAl Function in Incident HemoDialysis Patients (THREAD)

TypeinterventionalSponsorKyungpook National University HospitalRan2020 to 2023Enrolled80ConditionsEnd Stage Renal DiseaseArmsTheranova 400 dialyzer, High-flux dialyzer
NCT04247867 naunknown statusnot on this mapstarted 2020, after this paper: background citation

Combination of Medium Cut-off Dialyzer Membrane and Diet Modification to Alleviate Residual Uremic Syndrome of Dialysis Patients

TypeinterventionalSponsorUniversity Medical Centre LjubljanaRan2020 to 2022Enrolled50ConditionsEnd Stage Renal Disease, Haemodialysis, Diet, HealthyArmsmedium cut-off (MCO) dialysis membrane, Dietary fiber mixture (Plantago Psyllium and Inulin), Sodium propionate
NCT04260412 naunknown statusnot on this mapstarted 2020, after this paper: background citation

The Effect of Combining Medium Cut Off Polyarylethersulfone-polyvinylpyrrolidone Dialysis Membrane and Diet Modification on Reducing of Inflammation Response

TypeinterventionalSponsorUniversity Medical Centre LjubljanaRan2020 to 2022Enrolled50ConditionsEnd Stage Renal Disease, Haemodialysis, Diet, Healthy, Chronic InflammationArmsmedium cut-off (MCO) dialysis membrane, Dietary fiber mixture (Plantago Psyllium 69% and Inulin 30%), Sodium propionate
NCT04786535 naunknown statusnot on this mapstarted 2021, after this paper: background citation

Crossover Study of Three Groups Comparing the Efficacy of Uremic Toxins Clearance of Expanded Hemodialysis With Two Hemodialysis Membranes for Conventional Hemodialysis and Hemodiafiltration

TypeinterventionalSponsorInstituto Nacional de Ciencias Medicas y Nutricion Salvador ZubiranRan2021 to 2022Enrolled23ConditionsEnd Stage Renal DiseaseArmsExpanded Hemodialysis, High-flux Conventional Hemodialysis, Hemodiafiltration
NCT07679763 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Randomized Cross-Over Evaluation of Medium Cut-Off and High-Flux Hemodialysis Membranes on Inflammation and Cardiovascular Function in Maintenance Hemodialysis Patients

TypeinterventionalSponsorGazi UniversityRan2026 to 2027Enrolled30ConditionsEnd Stage Kidney Disease (ESKD), Hemodialysis, Cardiovascular Diseases (CVD), InflammationArmsMedium Cut-Off Hemodialysis Membrane, High-Flux Hemodialysis Membrane
NCT07685223 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Prospective Comparative Evaluation of the Effects of Medium Cut-Off and High-Flux Hemodialysis Membranes on Mineral and Bone Metabolism Biomarkers and Body Composition in Maintenance Hemodialysis Patients

TypeinterventionalSponsorGazi UniversityRan2026 to 2027Enrolled30ConditionsEnd Stage Kidney Disease (ESKD), Hemodialysis, Chronic Kidney Disease Mineral and Bone DisorderArmsMedium Cut-Off Hemodialysis Membrane, High-Flux Hemodialysis Membrane
3 · Its place in the literature

Who cites it

113 citing papers in PubMed, 4 syntheses or guidelines pooled it, 228 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Efficacy of medium cut-off dialyzers and comparison with high-flux dialyzers in patients on maintenance hemodialysis: A systematic review and meta-analysis.Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy · 2022
    Pooled it
  5. Trial
  6. Trial
  7. Trial
  8. Expanded hemodialysis as effective alternative to on-line hemodiafiltration: A randomized mid-term clinical trial.Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy · 2022
    Trial
  9. Trial
  10. Trial
  11. Trial
  12. Review
  13. Review
  14. Review
  15. Article
  16. Review
  17. Review
  18. Review
  19. Article
  20. Article

53 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors at 6 institutions in 4 countries.

Alexander H KirschClinical Division of Nephrology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.
Raphael LykoDivision of Nephrology, Department of Medicine, University Hospital, Würzburg, Germany.
Lars-Göran NilssonGambro Lundia AB, Baxter Renal Therapeutic Area, Lund, Sweden.
Werner BeckGambro Dialysatoren GmbH, Baxter Renal Therapeutic Area, Hechingen, Germany.
Michael AmdahlBaxter Healthcare Corporation, Life Science & Operations, Round Lake, IL, USA.
Petra LechnerDepartment of Internal Medicine, LKH Hochsteiermark, Bruck, Austria.
Andreas SchneiderDivision of Nephrology, Department of Medicine, University Hospital, Würzburg, Germany.
Christoph WannerDivision of Nephrology, Department of Medicine, University Hospital, Würzburg, Germany.
Alexander R RosenkranzClinical Division of Nephrology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.
Detlef H KrieterDivision of Nephrology, Department of Medicine, University Hospital, Würzburg, Germany.
Universitätsklinikum Würzburg · DEMedical University of Graz · ATBaxter (Germany) · DEBaxter (Sweden) · SEBaxter (United States) · USLKH Hochsteiermark · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Compared to high-flux dialysis membranes, novel medium cut-off (MCO) membranes show greater permeability for larger middle molecules. Methods: In two prospective, open-label, controlled, randomized, crossover pilot studies, 39 prevalent hemodialysis (HD) patients were studied in four dialysis treatments as follows: study 1, three MCO prototype dialyzers (AA, BB and CC with increasing permeability) and one high-flux dialyzer in HD; and study 2, two MCO prototype dialyzers (AA and BB) in HD and high-flux dialyzers in HD and hemodiafiltration (HDF). Primary outcome was lambda free light chain (λFLC) overall clearance. Secondary outcomes included overall clearances and pre-to-post-reduction ratios of middle and small molecules, and safety of MCO HD treatments. Results: MCO HD provided greater λFLC overall clearance [least square mean (standard error)] as follows: study 1: MCO AA 8.5 (0.54), MCO BB 11.3 (0.51), MCO CC 15.0 (0.53) versus high-flux HD 3.6 (0.51) mL/min; study 2: MCO AA 10.0 (0.58), MCO BB 12.5 (0.57) versus high-flux HD 4.4 (0.57) and HDF 6.2 (0.58) mL/min. Differences between MCO and high-flux dialyzers were consistently significant in mixed model analysis (each P < 0.001). Reduction ratios of λFLC were greater for MCO. Clearances of α1-microglobulin, complement factor D, kappa FLC (κFLC) and myoglobin were generally greater with MCO than with high-flux HD and similar to or greater than clearances with HDF. Albumin loss was moderate with MCO, but greater than with high-flux HD and HDF. Conclusions: MCO HD removes a wide range of middle molecules more effectively than high-flux HD and even exceeds the performance of high-volume HDF for large solutes, particularly λFLC.

Indexed as

AgedAlbuminsAlpha-GlobulinsCross-Over StudiesFemaleHemodiafiltrationHumansImmunoglobulin lambda-ChainsMaleMembranes, ArtificialMiddle AgedPermeabilityPilot ProjectsProspective StudiesRenal DialysisAlbuminsalpha-1-microglobulinAlpha-GlobulinsImmunoglobulin lambda-ChainsMembranes, Artificialbeta2-microglobulindialysishemodiafiltrationhemodialysisuremic toxins

Identifiers

PMID27587605
PMCPMC5837492
OpenAlexW2508561205

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

and 3 more above

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.