Evidence map›Paper›PMID 27586033›Full record

ArticleDigestive diseases and sciences2017

Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study.

Dechao Jiao, Kai Huang, Ming Zhu, Gang Wu, Jianzhuang Ren, Yanli Wang, Xinwei Han

Abstract read
PubMed Publisher
In one paragraph

Article in Digestive diseases and sciences, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Dechao JiaoDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Kai HuangDepartment of Oncology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, People's Republic of China.
Ming ZhuDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Gang WuDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Jianzhuang RenDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Yanli WangDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Xinwei HanDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China. 13592583911@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhether unilateral or bilateral drainage should be performed for malignant hilar biliary obstruction remains a matter of debate. Although a Y-stent with a central wide-open mesh facilitates bilateral stent placement, it has its own limitations.

aimThis study aims to evaluate the feasibility and efficacy of a newly designed Y-configured bilateral self-expanding metallic stent (SEMS) for the treatment of hilar biliary obstruction.

methodsIn this retrospective study, 14 consecutive patients with unresectable malignant hilar biliary obstruction (Bismuth type II or higher), who underwent placement of a newly designed Y-configured bilateral SEMS for hilar biliary obstruction from April 2013 to March 2015, were included into this study. Data on technical success, clinical success, stent patency, complications and patient survival were collected.

resultsTechnical and clinical success was 100 and 92.9 %, respectively. Mean serum bilirubin level was significantly decreased 1 month after stent placement (P < 0.01). Furthermore, two patients (14.3 %) had early complications (one patient had severe hemobilia and one patient had cholangitis), and two patients (14.3 %) had late complications (one patient had cholangitis and one patient had cholecystitis). During the mean follow-up period of 298 days (range 89-465 days), six patients (42.9 %) developed stent occlusion caused by tumor ingrowth or overgrowth (n = 5) and sludge (n = 1). Median stent patency and overall survival times were 281 days (95 % CI 175.9-386.1 days) and 381 days (95 % CI 291.4-470.6 days), respectively.

conclusionThe use of the newly designed Y-configured bilateral SEMS is feasible and effective for hilar biliary obstruction using port docking deployment.

Indexed as

Equipment DesignSelf Expandable Metallic StentsAgedAged, 80 and overBile Duct NeoplasmsBiliary Tract Surgical ProceduresCholangiopancreatography, Magnetic ResonanceCholangitisCholecystitisCholestasisDrainageFemaleHemobiliaHumansKlatskin TumorMagnetic Resonance ImagingFluoroscopyHilar biliary obstructionKlatskin tumorStent

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.