Evidence map›Paper›PMID 27584820›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2016

Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion.

Yongqiang Xu, Chuangxin Lin, Lifeng Zhang, Miaoxiong Lin, Jianqiang Lai, Shenglu Cao, Geng Peng, Kai Feng, Ge Yan, Daozhang Cai and 1 more

Abstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. [Study on the characteristics of biology force line of proximal femur based on structural topology optimization].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2019
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yongqiang XuDepartment of Orthopedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China (mainland).
Chuangxin LinDepartment of Orthopedics, The Third Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China (mainland).
Lifeng ZhangDepartment of Traumatology, The Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China (mainland).
Miaoxiong LinDepartment of Clinical Laboratory Medicine, Hospital of Traditional Chinese Medicine of Zhongshan, Zhongshan, Guangdong, China (mainland).
Jianqiang LaiDepartment of Orthopedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China (mainland).
Shenglu CaoDepartment of Orthopedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China (mainland).
Geng PengDepartment of Orthopedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China (mainland).
Kai FengDepartment of Orthopedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China (mainland).
Ge YanDepartment of Orthopedics, Hunan Provincial People's Hospital, Changsha, Hunan, China (mainland).
Daozhang CaiDepartment of Orthopedics, The Third Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China (mainland).
Gang WangDepartment of Orthopedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China (mainland).

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND The aim of this study was to provide valid data for a plate-screw fixation model for fractured posterior-anterior columns of the acetabulum. MATERIAL AND METHODS Nineteen cadaveric bony hemi-pelvis specimens were obtained and 50 healthy adults were enrolled. The modified Stoppa approach and computed tomography (CT) imaging were used to collect the measured parameter data of the module. RESULTS The measured parameter data were as follows: OP, 0.96±0.32 cm in females and 0.92±0.16 cm in males (P>0.05); PI, 0.98±0.28 cm in females, and 0.75±0.23 cm in males (P>0.05); Ðϴ, 59.68°±6.28° in females and 56.75°±3.22° in males (P>0.05); and Ðφ, 41.27°±2.76° in females and 34.31°±2.78° in males (P<0.05). The corresponding CT image data were as follows: PI, 1.08±0.22 cm in females and 0.85±0.27 cm in males (P>0.05); OP, 1.06±0.29 cm in females and 1.12±0.24 cm in males (P>0.05); Ðϴ, 55.33°±4.00° in females and 55. 50°±3.43° in males (P>0.05); and Ðφ was 39.21°±2.45°in females and 35.58°±2.31°in males (P<0.05). No significant difference with respect to sex and side existed between specimens and healthy adults (P>0.05). CONCLUSIONS The measured parameter data obtained in healthy adults and cadaveric specimens provided an anatomic basis for the designation of the guide module, and thus confirmed the accuracy and safety of screw placement in fractured columns of the acetabulum.

Indexed as

AcetabulumAdultAgedBone PlatesBone ScrewsCadaverFemaleFracture Fixation, InternalFractures, BoneHumansImage Processing, Computer-AssistedMaleMiddle AgedSurgery, Computer-AssistedTomography, X-Ray Computed

Identifiers

PMID27584820
PMCPMC5017690

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.