ArticleActa radiologica open2016

Can use of adaptive statistical iterative reconstruction reduce radiation dose in unenhanced head CT? An analysis of qualitative and quantitative image quality.

Bjørn Helge Østerås, Kristin Livelten Heggen, Hans Kristian Pedersen, Hilde Kjernlie Andersen, Anne Catrine T Martinsen

Open access · goldAbstract read
In one paragraph

Article in Acta radiologica open, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Bjørn Helge ØsteråsThe Intervention Centre, Oslo University Hospital, Postbox 4950, Nydalen, 0424 Oslo, Norway; Institute of Clinical Medicine, University of Oslo, 0027 Oslo, Norway.
Kristin Livelten HeggenDepartment of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway.
Hans Kristian PedersenDepartment of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway.
Hilde Kjernlie AndersenThe Intervention Centre, Oslo University Hospital, Postbox 4950, Nydalen, 0424 Oslo, Norway.
Anne Catrine T MartinsenThe Intervention Centre, Oslo University Hospital, Postbox 4950, Nydalen, 0424 Oslo, Norway; Institute of Physics, University of Oslo, 0027 Oslo, Norway.
Oslo University Hospital · NO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIterative reconstruction can reduce image noise and thereby facilitate dose reduction. PURPOSE: To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). MATERIAL AND

methodsFourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor's water phantom.

resultsThere was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between -3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and -7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content.

conclusionThere was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality.

Indexed as

Computed tomography (CT)head CTiterative reconstructionqualitative image qualityquantitative image qualityradiation dose

Identifiers

PMID27583169
PMCPMC4994404
OpenAlexW2513009869

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.