ArticleEar and hearing
Electrically Evoked Auditory Event-Related Responses in Patients with Auditory Brainstem Implants: Morphological Characteristics, Test-Retest Reliability, Effects of Stimulation Level, and Association with Auditory Detection.
Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 8 citations in OpenAlex.
- Article
- Article
- Pediatric Auditory Brainstem Implantation: Surgical, Electrophysiologic, and Behavioral Outcomes.Ear and hearingObservational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
objectiveThis study aimed to (1) characterize morphological characteristics of the electrically evoked cortical auditory event-related potentials (eERPs) and explore the potential association between onset eERP morphology and auditory versus nonauditory stimulation; (2) assess test-retest reliability of onset eERPs; (3) investigate effects of stimulation level on onset eERPs; and (4) explore the feasibility of using the onset eERP to estimate the lowest stimulation level that can be detected for individual stimulating electrodes in patients with auditory brainstem implants (ABIs).
designStudy participants included 5 children (S1 to S5) and 2 adults (S6 to S7) with unilateral Cochlear Nucleus 24M ABIs. Pediatric ABI recipients ranged in age from 2.6 to 10.2 years (mean: 5.2 years) at the time of testing. S6 and S7 were 21.2 and 24.6 years of age at the time of testing, respectively. S6 and S7 were diagnosed with neurofibromatosis II (NF2) and implanted with an ABI after a surgical removal of the tumors. All pediatric subjects received ABIs after being diagnosed with cochlear nerve deficiency. The lowest stimulation level that could be detected (behavioral T level) and the estimated maximum comfortable level (C level) was measured for individual electrodes using clinical procedures. For electrophysiological measures, the stimulus was a 100-msec biphasic pulse train that was delivered to individual electrodes in a monopolar-coupled stimulation mode at stimulation levels ranging from subthreshold to C levels. Electrophysiological recordings of the onset eERP were obtained in all subjects. For studies evaluating the test-retest reliability of the onset eERP, responses were measured using the same set of parameters in two test sessions. The time interval between test sessions ranged from 2 to 6 months. The lowest stimulation level that could evoke the onset eERP was defined as the objective T level.
resultsOnset eERPs were recorded in all subjects tested in this study. Inter- and intrasubject variations in morphological characteristics of onset eERPs were observed. Onset eERPs with complex waveforms were recorded for electrodes that evoked nonauditory sensations, based on feedback from subjects, as well as for electrodes without any indications of nonauditory stimulations. Onset eERPs in patients with ABIs demonstrated good test-retest reliability. Increasing stimulation levels resulted in increased eERP amplitudes but showed inconsistent effects on response latencies in patients with ABIs. Objective and behavioral T levels were correlated.
conclusionseERPs could be recorded in both non-NF2 and NF2 patients with ABIs. eERPs in both ABI patient groups show inter- and intrasubject variations in morphological characteristics. However, onset eERPs measured within the same subject in this study tended to be stable across study sessions. The onset eERP can potentially be used to estimate behavioral T levels in patients with ABIs. Further studies with more adult ABI recipients are warranted to investigate whether the onset eERP can be used to identify electrodes with nonauditory stimulations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.