ArticleJournal of synchrotron radiation2016
Diamond beamline I07: a beamline for surface and interface diffraction.
Article in Journal of synchrotron radiation, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 61 citations in OpenAlex.
- Evaporation of a Reactive Nanofluid Sessile Drop:Langmuir : the ACS journal of surfaces and colloids · 2025Article
- Characterization of cryo-cooled silicon crystal monochromators via measurement of flux versus power.Journal of synchrotron radiation · 2025Article
- Ultracompact Electrical Double Layers at TiOJournal of the American Chemical Society · 2024Article
- Structure Determination of FACS omega · 2024Article
- Opportunities and new developments for the study of surfaces and interfaces in soft condensed matter at the SIRIUS beamline of Synchrotron SOLEIL.Journal of synchrotron radiation · 2024Article
- Real-Time Monitoring of Strain Accumulation and Relief during Epitaxy of Ultrathin Co Ferrite Films with Varied Co Content.Materials (Basel, Switzerland) · 2023Article
- Effect of Anionic Lipids on Mammalian Plasma Cell Membrane Properties.Langmuir : the ACS journal of surfaces and colloids · 2023Article
- Influence of the Lipid Backbone on Electrochemical Phase Behavior.Langmuir : the ACS journal of surfaces and colloids · 2022Article
- Changes to lung surfactant monolayers upon exposure to gas phase ozone observed using X-ray and neutron reflectivity.Environmental science: atmospheres · 2022Article
- Templated electrodeposition as a scalable and surfactant-free approach to the synthesis of Au nanoparticles with tunable aspect ratios.Nanoscale advances · 2022Article
- Direct Experimental Evidence for Substrate Adatom Incorporation into a Molecular Overlayer.The journal of physical chemistry. C, Nanomaterials and interfaces · 2022Article
- Surface-controlled spatially heterogeneous physical properties of a supramolecular gel with homogeneous chemical composition.Chemical science · 2021Article
- Quantitative powder diffraction using a (2 + 3) surface diffractometer and an area detector.Journal of applied crystallography · 2021Article
- Water-Induced Reversal of the TiOThe journal of physical chemistry. C, Nanomaterials and interfaces · 2019Article
- Sample cell for studying liquid interfaces with an in situ electric field using X-ray reflectivity and application to clay particles at oil-oil interfaces.Journal of synchrotron radiation · 2018Article
- Understanding surface structure and chemistry of single crystal lanthanum aluminate.Scientific reports · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Beamline I07 at Diamond Light Source is dedicated to the study of the structure of surfaces and interfaces for a wide range of sample types, from soft matter to ultrahigh vacuum. The beamline operates in the energy range 8-30 keV and has two endstations. The first houses a 2+3 diffractometer, which acts as a versatile platform for grazing-incidence techniques including surface X-ray diffraction, grazing-incidence small- (and wide-) angle X-ray scattering, X-ray reflectivity and grazing-incidence X-ray diffraction. A method for deflecting the X-rays (a double-crystal deflector) has been designed and incorporated into this endstation, extending the surfaces that can be studied to include structures formed on liquid surfaces or at liquid-liquid interfaces. The second experimental hutch contains a similar diffractometer with a large environmental chamber mounted on it, dedicated to in situ ultrahigh-vacuum studies. It houses a range of complementary surface science equipment including a scanning tunnelling microscope, low-energy electron diffraction and X-ray photoelectron spectroscopy ensuring that correlations between the different techniques can be performed on the same sample, in the same chamber. This endstation allows accurate determination of well ordered structures, measurement of growth behaviour during molecular beam epitaxy and has also been used to measure coherent X-ray diffraction from nanoparticles during alloying.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.