Evidence map›Paper›PMID 27576350›Full record

ArticleBiomedical engineering online2016

An injection and mixing element for delivery and monitoring of inhaled nitric oxide.

Andrew R Martin, Chris Jackson, Samuel Fromont, Chloe Pont, Ira M Katz, Georges Caillobotte

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 3 countries.

Andrew R MartinDepartment of Mechanical Engineering, University of Alberta, 10-324 Donadeo Innovation Centre for Engineering, Edmonton, AB T6G 1H9, Canada. andrew.martin@ualberta.ca.
Chris JacksonVirginia Commonwealth University, Richmond, VA, 23284, USA.
Samuel FromontMedical R&D, Air Liquide Santé International, Centre de Recherche Paris-Saclay, 1 Chemin de la Porte des Loges, B.P. 126, 78354, Les Loges-en-Josas, France.
Chloe PontMedical R&D, Air Liquide Santé International, Centre de Recherche Paris-Saclay, 1 Chemin de la Porte des Loges, B.P. 126, 78354, Les Loges-en-Josas, France.
Ira M KatzMedical R&D, Air Liquide Santé International, Centre de Recherche Paris-Saclay, 1 Chemin de la Porte des Loges, B.P. 126, 78354, Les Loges-en-Josas, France.
Georges CaillobotteMedical R&D, Air Liquide Santé International, Centre de Recherche Paris-Saclay, 1 Chemin de la Porte des Loges, B.P. 126, 78354, Les Loges-en-Josas, France.
Air Liquide (France) · FRUniversity of Alberta · CAVirginia Commonwealth University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInhaled nitric oxide (NO) is a selective pulmonary vasodilator used primarily in the critical care setting for patients concurrently supported by invasive or noninvasive positive pressure ventilation. NO delivery devices interface with ventilator breathing circuits to inject NO in proportion with the flow of air/oxygen through the circuit, in order to maintain a constant, target concentration of inhaled NO.

methodsIn the present article, a NO injection and mixing element is presented. The device borrows from the design of static elements to promote rapid mixing of injected NO-containing gas with breathing circuit gases. Bench experiments are reported to demonstrate the improved mixing afforded by the injection and mixing element, as compared with conventional breathing circuit adapters, for NO injection into breathing circuits. Computational fluid dynamics simulations are also presented to illustrate mixing patterns and nitrogen dioxide production within the element.

resultsOver the range of air flow rates and target NO concentrations investigated, mixing length, defined as the downstream distance required for NO concentration to reach within ±5 % of the target concentration, was as high as 47 cm for the conventional breathing circuit adapters, but did not exceed 7.8 cm for the injection and mixing element.

conclusionThe injection and mixing element has potential to improve ease of use, compatibility and safety of inhaled NO administration with mechanical ventilators and gas delivery devices.

Indexed as

Administration, InhalationComputer SimulationHydrodynamicsInjectionsNitric OxideNitric Oxide

Identifiers

PMID27576350
PMCPMC5004310
OpenAlexW2517048368

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.