Evidence map›Paper›PMID 27574800›Full record

ArticlePloS one2016

Pupil Tracking for Real-Time Motion Corrected Anterior Segment Optical Coherence Tomography.

Oscar M Carrasco-Zevallos, Derek Nankivil, Christian Viehland, Brenton Keller, Joseph A Izatt

Abstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Embedded CPU-GPU pupil tracking.Biomedical optics express · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Hybrid FPGA-CPU pupil tracker.Biomedical optics express · 2021
    Article
  10. Biomedical optics express · 2021
    Article
  11. Article
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Oscar M Carrasco-ZevallosDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, United States of America.
Derek NankivilDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, United States of America.
Christian ViehlandDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, United States of America.
Brenton KellerDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, United States of America.
Joseph A IzattDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, United States of America.

Funding

Intraoperative OCT Guidance of Intraocular SurgeryR01EY023039 · NEI · DUKE UNIVERSITY · PI IZATT, JOSEPH A, TOTH, CYNTHIA ANN · 2013 to 2016
$3.9M
NEI NIH HHS R01 EY023039
6 · The paper itself

Abstract

Volumetric acquisition with anterior segment optical coherence tomography (ASOCT) is necessary to obtain accurate representations of the tissue structure and to account for asymmetries of the anterior eye anatomy. Additionally, recent interest in imaging of anterior segment vasculature and aqueous humor flow resulted in application of OCT angiography techniques to generate en face and 3D micro-vasculature maps of the anterior segment. Unfortunately, ASOCT structural and vasculature imaging systems do not capture volumes instantaneously and are subject to motion artifacts due to involuntary eye motion that may hinder their accuracy and repeatability. Several groups have demonstrated real-time tracking for motion-compensated in vivo OCT retinal imaging, but these techniques are not applicable in the anterior segment. In this work, we demonstrate a simple and low-cost pupil tracking system integrated into a custom swept-source OCT system for real-time motion-compensated anterior segment volumetric imaging. Pupil oculography hardware coaxial with the swept-source OCT system enabled fast detection and tracking of the pupil centroid. The pupil tracking ASOCT system with a field of view of 15 x 15 mm achieved diffraction-limited imaging over a lateral tracking range of +/- 2.5 mm and was able to correct eye motion at up to 22 Hz. Pupil tracking ASOCT offers a novel real-time motion compensation approach that may facilitate accurate and reproducible anterior segment imaging.

Indexed as

Anterior Eye SegmentArtifactsHumansImaging, Three-DimensionalMotionPupilTomography, Optical Coherence

Identifiers

PMID27574800
PMCPMC5004917

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.