Evidence map›Paper›PMID 27565136›Full record

ArticleCancer imaging : the official publication of the International Cancer Imaging Society2016

A method to assess image quality for Low-dose PET: analysis of SNR, CNR, bias and image noise.

Jianhua Yan, Josh Schaefferkoette, Maurizio Conti, David Townsend

Erratum issuedAbstract read
In one paragraph

Article in Cancer imaging : the official publication of the International Cancer Imaging Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 58 papers.

0numbers the graph read from it
0cells of the map it votes in
58citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

58 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Optimization of Administered Activity forWorld journal of nuclear medicine · 2026
    Article
  6. On Hallucinations in Artificial Intelligence-Generated Content for Nuclear Medicine Imaging (the DREAM Report).Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
    Review
  7. Article
  8. Lung lesion detectability on images obtained from decimated and CNN-based denoised [European journal of nuclear medicine and molecular imaging · 2025
    Article
  9. Lymphoma Therapy Response Assessment with Low-Dose [Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2025
    Article
  10. Diagnostic accuracy in NSCLC lymph node staging with Total-Body and conventional PET/CT.European journal of nuclear medicine and molecular imaging · 2025
    Article
  11. Article
  12. Ultra-low dose immunoPET usingFrontiers in medicine · 2025
    Article
  13. Article
  14. Article
  15. Article
  16. Dose Reduction in Pediatric Oncology Patients with Delayed Total-Body [Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2024
    Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Jianhua YanDepartment of Nuclear Medicine, First Hospital of Shanxi Medical University, 85 Jiefang S Rd, Yingze, Taiyuan, Shanxi, 030001, China. jianhua.yan@gmail.com.
Josh SchaefferkoetteA*STAR-NUS, Clinical Imaging Research Center, Center for translational medicine, 14 medical drive, #B1-01, 17599, Singapore, Singapore.
Maurizio ContiSiemens Healthcare Molecular Imaging, 810 Innovation Drive, Knoxville, TN37932, USA.
David TownsendA*STAR-NUS, Clinical Imaging Research Center, Center for translational medicine, 14 medical drive, #B1-01, 17599, Singapore, Singapore.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLowering injected dose will have an effect on PET image quality. In this article, we aim to investigate this effect in terms of signal-to-noise ratio (SNR) in the liver, contrast-to-noise ratio (CNR) in the lesion, bias and ensemble image noise.

methodsWe present here our method and preliminary results using tuberculosis (TB) cases. Sixteen patients who underwent (18)F-FDG PET/MR scans covering the whole lung and portion of the liver were selected for the study. Reduced doses were simulated by randomly discarding events in the PET list mode data stream, and ten realizations at each simulated dose were generated and reconstructed. The volumes of interest (VOI) were delineated on the image reconstructed from the original full statistics data for each patient. Four thresholds (20, 40, 60 and 80 % of SUVmax) were used to quantify the effect of the threshold on CNR at the different count level. Image metrics were calculated for each VOI. This experiment allowed us to quantify the loss of SNR and CNR as a function of the counts in the scan, in turn related to dose injected. Reproducibility of mean and maximum standardized uptake value (SUVmean and SUVmax) measurement in the lesions was studied as standard deviation across 10 realizations.

resultsAt 5 × 10(6) counts in the scan, the average SNR in the liver in the observed samples is about 3, and the CNR is reduced to 60 % of the full statistics value. The CNR in the lesion and SNR in the liver decreased with reducing count data. The variation of CNR across the four thresholds does not significantly change until the count level of 5 × 10(6). After correcting the factor related to subject's weight, the square of the SNR in the liver was found to have a very good linear relationship with detected counts. Some quantitative bias appears with count reduction. At the count level of 5 × 10(6), bias and noise in terms of SUVmean and SUVmax are up to 10 and 20 %, respectively. To keep both bias and noise less than 10 %, 5 × 10(6) counts and 20 × 10(6) counts were required for SUVmean and SUVmax, respectively.

conclusionsInitial results with the given data of 16 patients diagnosed as TB demonstrated that 5 × 10(6) counts in the scan could be sufficient to yield good images in terms of SNR, CNR, bias and noise. In the future, more work needs to be done to validate the proposed method with a larger population and lung cancer patient data.

Indexed as

Dose-Response Relationship, RadiationFluorodeoxyglucose F18HumansPositron-Emission TomographyRadiopharmaceuticalsReproducibility of ResultsSignal-To-Noise RatioFluorodeoxyglucose F18RadiopharmaceuticalsImage qualityLow doseLungPET/CTPET/MR

Identifiers

PMID27565136
PMCPMC5002150

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.