Evidence map›Paper›PMID 27558535›Full record

ArticleAnalytical chemistry2016

Cancer Diagnostics via Ultrasensitive Multiplexed Detection of Parathyroid Hormone-Related Peptides with a Microfluidic Immunoarray.

Brunah A Otieno, Colleen E Krause, Abby L Jones, Richard B Kremer, James F Rusling

Open access · greenAbstract readValidation Study
In one paragraph

Article in Analytical chemistry, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
3.2field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 58 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Multiplexed electrochemical assays for clinical applications.Current opinion in electrochemistry · 2023
    Article
  7. Review
  8. Article
  9. Article
  10. Review
  11. Review
  12. Article
  13. Article
  14. Review
  15. 3D-Printed Immunosensor Arrays for Cancer Diagnostics.Sensors (Basel, Switzerland) · 2020
    Review
  16. Article
  17. Article
  18. Article
  19. Review
  20. Multiplexed Point-of-Care Testing - xPOCT.Trends in biotechnology · 2017
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 3 countries.

Brunah A OtienoDepartment of Chemistry, University of Connecticut , Storrs, Connecticut 06269, United States.
Colleen E KrauseDepartment of Chemistry, University of Connecticut , Storrs, Connecticut 06269, United States.
Abby L JonesDepartment of Chemistry, University of Connecticut , Storrs, Connecticut 06269, United States.
Richard B KremerDepartment of Medicine, McGill University , Montreal, Quebec H3A 1A1, Canada.
James F RuslingDepartment of Chemistry, University of Connecticut , Storrs, Connecticut 06269, United States.
University of Connecticut · USMcGill University · CAUniversity of Hartford · US

Funding

Protein Biomarker Arrays for Personalized Treatment of Prostate CancerR01EB016707 · NIBIB · UNIVERSITY OF CONNECTICUT STORRS · PI RUSLING, JAMES F. · 2014 to 2017
$1.4M
Protein Biosensor Arrays Based on NanomaterialsR01EB014586 · NIBIB · UNIVERSITY OF CONNECTICUT STORRS · PI RUSLING, JAMES F. · 2011 to 2014
$1.4M
NIBIB NIH HHS R01 EB014586NIBIB NIH HHS R01 EB016707
6 · The paper itself

Abstract

Parathyroid hormone-related peptide (PTHrP) is recognized as the major causative agent of humoral hypercalcemia of malignancy (HHM). The paraneoplastic PTHrP has also been implicated in tumor progression and metastasis of many human cancers. Conventional PTHrP detection methods like immunoradiometric assay (IRMA) lack the sensitivity required to measure target peptide levels prior to the development of hypercalcemia. In general, sensitive, multiplexed peptide measurement by immunoassay represents challenges that we address in this paper. We describe here the first ultrasensitive multiplexed peptide assay to measure intact PTHrP 1-173 as well as circulating N-terminal and C-terminal peptide fragments. This versatile approach should apply to almost any collection of peptides that are long enough to present binding sites for two antibodies. To target PTHrP, we employed a microfluidic immunoarray featuring a chamber for online capture of the peptides from serum onto magnetic beads decorated with massive numbers of peptide-specific antibodies and enzyme labels. Magnetic bead-peptide conjugates were then washed and sent to a detection chamber housing an antibody-modified 8-electrode array fabricated by inkjet printing of gold nanoparticles. Limits of detection (LODs) of 150 aM (∼1000-fold lower than IRMA) in 5 μL of serum were achieved for simultaneous detection of PTHrP isoforms and peptide fragments in 30 min. Good correlation for patient samples was found with IRMA (n = 57); r(2) = 0.99 assaying PTHrP 1-86 equiv fragments. Analysis by a receiver operating characteristic (ROC) plot gave an area under the curve of 0.96, 80-83% clinical sensitivity, and 96-100% clinical specificity. Results suggest that PTHrP1-173 isoform and its short C-terminal fragments are the predominant circulating forms of PTHrP. This new ultrasensitive, multiplexed assay for PTHrP and fragments is promising for clinical diagnosis, prognosis, and therapeutic monitoring from early to advanced stage cancer patients and to examine underlying mechanisms of PTHrP overproduction.

Indexed as

Antibodies, ImmobilizedEquipment DesignHumansImmunoassayLimit of DetectionNeoplasmsParathyroid Hormone-Related ProteinProtein Array AnalysisProtein IsoformsAntibodies, ImmobilizedParathyroid Hormone-Related ProteinProtein Isoforms

Identifiers

PMID27558535
PMCPMC5032051
OpenAlexW2507949298

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.