Evidence map›Paper›PMID 27556071›Full record

ArticleEndoscopy international open2016

Accuracy of polyp localization at colonoscopy.

Sam A O'Connor, David G Hewett, Marcus O Watson, Bradley J Kendall, Luke F Hourigan, Gerald Holtmann

Open access · goldAbstract read
In one paragraph

Article in Endoscopy international open, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Sam A O'ConnorDepartment of Gastroenterology and Hepatology, Princess Alexandra Hospital;; School of Medicine, The University of Queensland;
David G HewettSchool of Medicine, The University of Queensland;; Department of Gastroenterology, Queen Elizabeth II Jubilee Hospital;
Marcus O WatsonSchool of Medicine, The University of Queensland;; Queensland Health Clinical Skills Development Service;
Bradley J KendallDepartment of Gastroenterology and Hepatology, Princess Alexandra Hospital;; School of Medicine, The University of Queensland;
Luke F HouriganDepartment of Gastroenterology and Hepatology, Princess Alexandra Hospital;
Gerald HoltmannDepartment of Gastroenterology and Hepatology, Princess Alexandra Hospital;; Faculty of Medicine and Biomedical Sciences, & Faculty of Health and Behavioural Sciences, The University of Queensland; Brisbane, AUSTRALIA.
The University of Queensland · AUPrincess Alexandra Hospital · GBQueensland Health · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND STUDY

aimsAccurate documentation of lesion localization at the time of colonoscopic polypectomy is important for future surveillance, management of complications such as delayed bleeding, and for guiding surgical resection. We aimed to assess the accuracy of endoscopic localization of polyps during colonoscopy and examine variables that may influence this accuracy. PATIENTS AND

methodsWe conducted a prospective observational study in consecutive patients presenting for elective, outpatient colonoscopy. All procedures were performed by Australian certified colonoscopists. The endoscopic location of each polyp was reported by the colonoscopist at the time of resection and prospectively recorded. Magnetic endoscope imaging was used to determine polyp location, and colonoscopists were blinded to this image. Three experienced colonoscopists, blinded to the endoscopist's assessment of polyp location, independently scored the magnetic endoscope images to obtain a reference standard for polyp location (Cronbach alpha 0.98). The accuracy of colonoscopist polyp localization using this reference standard was assessed, and colonoscopist, procedural and patient variables affecting accuracy were evaluated.

resultsA total of 155 patients were enrolled and 282 polyps were resected in 95 patients by 14 colonoscopists. The overall accuracy of polyp localization was 85 % (95 % confidence interval, CI; 60 - 96 %). Accuracy varied significantly (P < 0.001) by colonic segment: caecum 100 %, ascending 77 % (CI;65 - 90), transverse 84 % (CI;75 - 92), descending 56 % (CI;32 - 81), sigmoid 88 % (CI;79 - 97), rectum 96 % (CI;90 - 101). There were significant differences in accuracy between colonoscopists (P < 0.001), and colonoscopist experience was a significant independent predictor of accuracy (OR 3.5, P = 0.028) after adjustment for patient and procedural variables.

conclusionsAccuracy of localization of polyps is imprecise and affected by position within the colon and colonoscopist, including their level of experience. Magnetic endoscope imaging may improve the localization of lesions during colonoscopy.

Identifiers

PMID27556071
PMCPMC4993896
OpenAlexW2403544937

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.