Evidence map›Paper›PMID 27553930›Full record

ArticleEuropean radiology2017

Comparison of videofluoroscopy and impedance planimetry for the evaluation of oesophageal stenosis: a retrospective study.

Martina Scharitzer, Johannes Lenglinger, Wolfgang Schima, Michael Weber, Claudia Ringhofer, Peter Pokieser

Open access · hybridAbstract readComparative Study
In one paragraph

Article in European radiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Guideline
  2. Oesophageal fluoroscopy in adults-when and why?The British journal of radiology · 2024
    Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Martina ScharitzerDepartment of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria. martina.scharitzer@meduniwien.ac.at.ORCID http://orcid.org/0000-0003-4427-5463
Johannes LenglingerDepartment of Visceral Surgery and Medicine, University Hospital Bern, Bern, Switzerland.
Wolfgang SchimaDepartment of Diagnostic and Interventional Radiology, KH Goettlicher Heiland, KH der Barmherzigen Schwestern, St. Josef-KH, Vienna, Austria.
Michael WeberDepartment of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria.
Claudia RinghoferDepartment of Surgery, Medical University of Vienna, Vienna, Austria.
Peter PokieserUnified Patient Division, Teaching Center, Medical University of Vienna, Vienna, Austria.
Medical University of Vienna · ATUniversity Hospital of Bern · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo compare videofluoroscopy that included a tablet test with impedance planimetry (EndoFLIP

methodsIn 56 patients, videofluoroscopic examinations following the transit of a 14-mm tablet were retrospectively reviewed and correlated with impedance planimetry findings, a catheter-based method using impedance planimetry to display the oesophageal diameter estimates. Additional findings assessed were the occurrence of symptoms during tablet passage and evaluation of oesophageal motility.

resultsImpaction of the tablet occurred in 31/56 patients; nine showed a moderate delay (2-15 s), three a short delay (<2 s) and 13 no delay of tablet passage. Both methods showed a significant correlation between tablet impaction and oesophageal diameter <15.1 mm, as measured by impedance planimetry (p = 0.035). The feeling of the tablet getting stuck was reported by seven patients, six showing impaction of the tablet (four with an EndoFLIP-diameter < 13 mm, two with a diameter of 13-19 mm) and one showing delayed passage (EndoFLIP diameter of 17 mm).

conclusionsVideofluoroscopy and impedance planimetry correlate significantly regarding tablet impaction and residual oesophageal lumen. A standardized 14-mm tablet is helpful in demonstrating oesophageal strictures in dysphagic patients. Triggering of subjective symptoms provides valuable information during a videofluoroscopic study. KEY POINTS: • A 14-mm tablet can demonstrate oesophagogastric junction narrowing in patients with dysphagia. • Type of passage of a tablet enables estimation of oesophageal luminal diameter. • Videofluoroscopy and impedance planimetry correlate significantly regarding tablet impaction and residual oesophageal lumen.

Indexed as

AdolescentAdultAgedAged, 80 and overDeglutition DisordersElectric ImpedanceEsophageal StenosisEsophagogastric JunctionFemaleFluoroscopyHumansMaleManometryMiddle AgedRetrospective StudiesTabletsTabletsCineradiographyDeglutition disordersImpedance planimetryOesophageal stenosisTablets

Identifiers

PMID27553930
PMCPMC5334389
OpenAlexW2514580641

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.