Evidence map›Paper›PMID 27547034›Full record

ArticleInternational journal of nanomedicine2016

Augmenting regional and targeted delivery in the pulmonary acinus using magnetic particles.

Yan Ostrovski, Philipp Hofemeier, Josué Sznitman

Abstract read
In one paragraph

Article in International journal of nanomedicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Magnetic particle targeting for diagnosis and therapy of lung cancers.Journal of controlled release : official journal of the Controlled Release Society · 2020
    Review
  8. Article
  9. Article
  10. Article
  11. [Progress on numerical simulation of the deposition of inhaled particles in human pulmonary acinus region].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2019
    Review
  12. Review
  13. Article
  14. Article
  15. One (sub-)acinus for all: Fate of inhaled aerosols in heterogeneous pulmonary acinar structures.European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences · 2018
    Review
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yan OstrovskiDepartment of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel.
Philipp HofemeierDepartment of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel.
Josué SznitmanDepartment of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel.

Funding

European Research Council 677772
6 · The paper itself

Abstract

backgroundIt has been hypothesized that by coupling magnetic particles to inhaled therapeutics, the ability to target specific lung regions (eg, only acinar deposition), or even more so specific points in the lung (eg, tumor targeting), can be substantially improved. Although this method has been proven feasible in seminal in vivo studies, there is still a wide gap in our basic understanding of the transport phenomena of magnetic particles in the pulmonary acinar regions of the lungs, including particle dynamics and deposition characteristics.

methodsHere, we present computational fluid dynamics-discrete element method simulations of magnetically loaded microdroplet carriers in an anatomically inspired, space-filling, multi-generation acinar airway tree. Breathing motion is modeled by kinematic sinusoidal displacements of the acinar walls, during which droplets are inhaled and exhaled. Particle dynamics are governed by viscous drag, gravity, and Brownian motion as well as the external magnetic force. In particular, we examined the roles of droplet diameter and volume fraction of magnetic material within the droplets under two different breathing maneuvers. RESULTS AND DISCUSSION: Our results indicate that by using magnetic-loaded droplets, 100% of the particles that enter are deposited in the acinar region. This is consistent across all particle sizes investigated (ie, 0.5-3.0 µm). This is best achieved through a deep inhalation maneuver combined with a breath-hold. Particles are found to penetrate deep into the acinus and disperse well, while the required amount of magnetic material is maintained low (<2.5%). Although particles in the size range of ~90-500 nm typically show the lowest deposition fractions, our results suggest that this feature could be leveraged to augment targeted delivery.

Indexed as

Models, BiologicalAdministration, InhalationAerosolsBreath HoldingComputer SimulationDrug CarriersHumansHydrodynamicsLungMagnetic PhenomenaNebulizers and VaporizersParticle SizePulmonary AlveoliRespirationAerosolsDrug CarriersaerosolCFDinhalation medicineSPIONstargeted delivery

Identifiers

PMID27547034
PMCPMC4968997

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.