The usability of ventilators: a comparative evaluation of use safety and user experience.

Plinio P Morita, Peter B Weinstein, Christopher J Flewwelling, Carleene A Bañez, Tabitha A Chiu, Mario Iannuzzi, Aastha H Patel, Ashleigh P Shier, Joseph A Cafazzo

Abstract readLetter
In one paragraph

Article in Critical care (London, England), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Article
  2. Respiratory therapists' perceptions of electrical impedance tomography in pediatric intensive care: A mixed methods implementation study.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2026
    Article
  3. Article
  4. Article
  5. Review
  6. Usability Study on Patient Monitoring Systems: An Evaluation of a User Interface Based on User Experience and Preference.Medical science monitor : international medical journal of experimental and clinical research · 2023
    Article
  7. Article
  8. Article
  9. Article
  10. The novel Mechanical Ventilator Milano for the COVID-19 pandemic.Physics of fluids (Woodbury, N.Y. : 1994) · 2021
    Article
  11. Article
  12. Human factors/ergonomics to support the design and testing of rapidly manufactured ventilators in the UK during the COVID-19 pandemic.International journal for quality in health care : journal of the International Society for Quality in Health Care · 2021
    Article
  13. Article
  14. Comprehensive Evaluation of User Interface for Ventilators Based on Respiratory Therapists' Performance, Workload, and User Experience.Medical science monitor : international medical journal of experimental and clinical research · 2018
    Article
  15. Usability Study of the User-Interface of Intensive Care Ventilators Based on User Test and Eye-Tracking Signals.Medical science monitor : international medical journal of experimental and clinical research · 2018
    Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors.

Plinio P MoritaHealthcare Human Factors, Techna Institute, University Health Network, Toronto, Canada.
Peter B WeinsteinHealthcare Human Factors, Techna Institute, University Health Network, Toronto, Canada.
Christopher J FlewwellingHealthcare Human Factors, Techna Institute, University Health Network, Toronto, Canada.
Carleene A BañezHealthcare Human Factors, Techna Institute, University Health Network, Toronto, Canada.
Tabitha A ChiuHealthcare Human Factors, Techna Institute, University Health Network, Toronto, Canada.
Mario IannuzziHealthcare Human Factors, Techna Institute, University Health Network, Toronto, Canada.
Aastha H PatelHealthcare Human Factors, Techna Institute, University Health Network, Toronto, Canada.
Ashleigh P ShierHealthcare Human Factors, Techna Institute, University Health Network, Toronto, Canada.
Joseph A CafazzoHealthcare Human Factors, Techna Institute, University Health Network, Toronto, Canada. Joe.Cafazzo@uhn.ca.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe design complexity of critical care ventilators (CCVs) can lead to use errors and patient harm. In this study, we present the results of a comparison of four CCVs from market leaders, using a rigorous methodology for the evaluation of use safety and user experience of medical devices.

methodsWe carried out a comparative usability study of four CCVs: Hamilton G5, Puritan Bennett 980, Maquet SERVO-U, and Dräger Evita V500. Forty-eight critical care respiratory therapists participated in this fully counterbalanced, repeated measures study. Participants completed seven clinical scenarios composed of 16 tasks on each ventilator. Use safety was measured by percentage of tasks with use errors or close calls (UE/CCs). User experience was measured by system usability and workload metrics, using the Post-Study System Usability Questionnaire (PSSUQ) and the National Aeronautics and Space Administration Task Load Index (NASA-TLX).

resultsNine of 18 post hoc contrasts between pairs of ventilators were significant after Bonferroni correction, with effect sizes between 0.4 and 1.09 (Cohen's d). There were significantly fewer UE/CCs with SERVO-U when compared to G5 (p = 0.044) and V500 (p = 0.020). Participants reported higher system usability for G5 when compared to PB980 (p = 0.035) and higher system usability for SERVO-U when compared to G5 (p < 0.001), PB980 (p < 0.001), and V500 (p < 0.001). Participants reported lower workload for G5 when compared to PB980 (p < 0.001) and lower workload for SERVO-U when compared to PB980 (p < 0.001) and V500 (p < 0.001). G5 scored better on two of nine possible comparisons; SERVO-U scored better on seven of nine possible comparisons. Aspects influencing participants' performance and perception include the low sensitivity of G5's touchscreen and the positive effect from the quality of SERVO-U's user interface design.

conclusionsThis study provides empirical evidence of how four ventilators from market leaders compare and highlights the importance of medical technology design. Within the boundaries of this study, we can infer that SERVO-U demonstrated the highest levels of use safety and user experience, followed by G5. Based on qualitative data, differences in outcomes could be explained by interaction design, quality of hardware components used in manufacturing, and influence of consumer product technology on users' expectations.

Indexed as

Critical CareEquipment DesignHealth PersonnelHumansIntensive Care UnitsPatient SafetyRespiration, ArtificialVentilators, MechanicalComparative studyCritical careHuman factors and ergonomicsMechanicalMedical device designPatient safetyVentilator

Identifiers

PMID27542352
PMCPMC4992292

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.