Evidence map›Paper›PMID 27539550›Full record

SynthesisScientific reports2016

Efficacy of Electrical Stimulators for Bone Healing: A Meta-Analysis of Randomized Sham-Controlled Trials.

Ilyas S Aleem, Idris Aleem, Nathan Evaniew, Jason W Busse, Michael Yaszemski, Arnav Agarwal, Thomas Einhorn, Mohit Bhandari

Abstract readMeta-AnalysisReview
In one paragraph

Synthesis in Scientific reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

47 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Thromboprophylactic Efficacy and Safety of Anticoagulants After Arthroscopic Knee Surgery: A Systematic Review and Meta-Analysis.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis
    Pooled it
  3. Article
  4. Electrical Stimulation Directs Formation of Perfused Vasculature in Engineered Tissues.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Review
  10. Article
  11. Technology behind augmenting fracture healing.Bulletin of the Hospital for Joint Disease (2013) · 2025
    Review
  12. Review
  13. Review
  14. Review
  15. Review
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ilyas S AleemDivision of Orthopaedics, Department of Surgery, McMaster University, Hamilton, ON, Canada.
Idris AleemThalmic Labs, Kitchener, ON, Canada.
Nathan EvaniewDivision of Orthopaedics, Department of Surgery, McMaster University, Hamilton, ON, Canada.
Jason W BusseDepartment of Clinical Epidemiology and Biostatistics, McMaster University, Hamilton, ON, Canada.
Michael YaszemskiDepartment of Orthopaedics, Mayo Clinic, Rochester, MN, USA.
Arnav AgarwalUniversity of Toronto Faculty of Medicine, Toronto, ON, Canada.
Thomas EinhornDepartment of Orthopaedic Surgery, New York University Langone Medical Center, New York, NY, USA.
Mohit BhandariDivision of Orthopaedics, Department of Surgery, McMaster University, Hamilton, ON, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrical stimulation is a common adjunct used to promote bone healing; its efficacy, however, remains uncertain. We conducted a meta-analysis of randomized sham-controlled trials to establish the efficacy of electrical stimulation for bone healing. We identified all trials randomizing patients to electrical or sham stimulation for bone healing. Outcomes were pain relief, functional improvement, and radiographic nonunion. Two reviewers assessed eligibility and risk of bias, performed data extraction, and rated the quality of the evidence. Fifteen trials met our inclusion criteria. Moderate quality evidence from 4 trials found that stimulation produced a significant improvement in pain (mean difference (MD) on 100-millimeter visual analogue scale = -7.7 mm; 95% CI -13.92 to -1.43; p = 0.02). Two trials found no difference in functional outcome (MD = -0.88; 95% CI -6.63 to 4.87; p = 0.76). Moderate quality evidence from 15 trials found that stimulation reduced radiographic nonunion rates by 35% (95% CI 19% to 47%; number needed to treat = 7; p < 0.01). Patients treated with electrical stimulation as an adjunct for bone healing have less pain and are at reduced risk for radiographic nonunion; functional outcome data are limited and requires increased focus in future trials.

Indexed as

Fracture HealingElectric Stimulation TherapyFemaleFractures, BoneHumansMaleRandomized Controlled Trials as Topic

Identifiers

PMID27539550
PMCPMC4990885

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.