ArticleClinical orthopaedics and related research2016
Head-Neck Osteoplasty has Minor Effect on the Strength of an Ovine Cam-FAI Model: In Vitro and Finite Element Analyses.
Article in Clinical orthopaedics and related research, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 17 citations in OpenAlex.
- In Vitro Ovine Cam Impingement Model and Its Effect on Acetabular Cartilage.Orthopaedic journal of sports medicine · 2025Article
- Developing and Validating a Model of Humeral Stem Primary Stability, Intended for In Silico Clinical Trials.Annals of biomedical engineering · 2024Article
- Do dGEMRIC and T2 Imaging Correlate With Histologic Cartilage Degeneration in an Experimental Ovine FAI Model?Clinical orthopaedics and related research · 2019Article
- CORR Insights®: Cam FAI and Smaller Neck Angles Increase Subchondral Bone Stresses During Squatting: A Finite Element Analysis.Clinical orthopaedics and related research · 2019Article
- CORR Insights®: What Are the Reference Values and Associated Factors for Center-edge Angle and Alpha Angle? A Population-based Study.Clinical orthopaedics and related research · 2018Article
- Biomechanical features of six design of the delta external fixator for treating Pilon fracture: a finite element study.Medical & biological engineering & computing · 2018Article
- Does Removal of Subchondral Cortical Bone Provide Sufficient Resection Depth for Treatment of Cam Femoroacetabular Impingement?Clinical orthopaedics and related research · 2017Article
- Femoral neck fractures as a complication of hip arthroscopy: a systematic review.Journal of hip preservation surgery · 2017Review
Corrections and comments
- Commented on byCORR Insights2016
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundOsteochondroplasty of the head-neck region is performed on patients with cam femoroacetabular impingement (FAI) without fully understanding its repercussion on the integrity of the femur. Cam-type FAI can be surgically and reproducibly induced in the ovine femur, which makes it suitable for studying corrective surgery in a consistent way. Finite element models built on quantitative CT (QCT) are computer tools that can be used to predict femoral strength and evaluate the mechanical effect of surgical correction. QUESTIONS/PURPOSES: We asked: (1) What is the effect of a resection of the superolateral aspect of the ovine femoral head-neck junction on failure load? (2) How does the failure load after osteochondroplasty compare with reported forces from activities of daily living in sheep? (3) How do failure loads and failure locations from the computer simulations compare with the experiments?
methodsOsteochondroplasties (3, 6, 9 mm) were performed on one side of 18 ovine femoral pairs with the contralateral intact side as a control. The 36 femurs were scanned via QCT from which specimen-specific computer models were built. Destructive compression tests then were conducted experimentally using a servohydraulic testing system and numerically via the computer models. Safety factors were calculated as the ratio of the maximal force measured in vivo by telemeterized hip implants during the sheep's walking and running activities to the failure load. The simulated failure loads and failure locations from the computer models were compared with the experimental results.
resultsFailure loads were reduced by 5% (95% CI, 2%-8%) for the 3-mm group (p = 0.0089), 10% (95% CI, 6%-14%) for the 6-mm group (p = 0.0015), and 19% (95% CI, 13%-26%) for the 9-mm group (p = 0.0097) compared with the controls. Yet, the weakest specimen still supported more than 2.4 times the peak load during running. Strong correspondence was found between the simulated and experimental failure loads (R
conclusionsThe resistance of ovine femurs to fracture decreased with deeper resections. However, under in vitro testing conditions, the effect on femoral strength remains small even after 9 mm correction, suggesting that femoral head-neck osteochondroplasty could be done safely on the ovine femur. QCT-based finite element models were able to predict weakening of the femur resulting from the osteochondroplasty. CLINICAL RELEVANCE: The ovine femur provides a seemingly safe platform for scientific evaluation of FAI. It also appears that computer models based on preoperative CT scans may have the potential to provide patient-specific guidelines for preventing overcorrection of cam FAI.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.